Literature DB >> 16721270

Decreased supply-dependent oxygen consumption in the skeletal muscle of the spontaneously hypertensive rat during acute hypoxia.

Lane M Smith1, R Wayne Barbee, Kevin R Ward, Roland N Pittman.   

Abstract

The purpose of this study was to correlate microvascular oxygen delivery (DO2) and consumption (VO2) in the skeletal muscle of spontaneously hypertensive rats (SHRs) and Wistar Kyoto rats (WKY) with hemodynamics during acute hypoxia. We expected greater abnormalities in central and microvascular hemodynamics during hypoxic induced shock in the SHR compared with the WKY due to microvascular rarefaction. The inspired oxygen fraction (FiO2) was lowered from 0.21 to 0.15, 0.1, 0.08, and 0.05 in anesthetized, mechanically ventilated rats. Lactate and base deficit values were similar for both groups at 0.21 and 0.15 FiO2, but higher in SHR at lower FiO2. Baseline aortic blood flow (SHR, 56.2+/-4.0 mL min; WKY, 61.8+/-5.3 mL min) and systemic DO2 (SHR, 9.02+/-0.82 mL min; WKY, 9.32+/-0.54 mL min) increased similarly when FiO2 was lowered to 0.15. Further reductions in FiO2 caused lower aortic flow and systemic DO2 in the SHR than WKY at 0.08 and 0.05 FiO2. Spinotrapezius blood flow increased from baseline (SHR, 24.8+/-1.8 nL s; WKY, 22.7+/-2.1 nL s) in both groups when FiO2 was reduced to 0.15; further reductions in FiO2 decreased blood flow in both groups, with lower values in the SHR group at 0.1 and 0.08 FiO2. The SHR group demonstrated higher venous oxygen saturation at low values of FiO2 compared with WKY. This reduced oxygen extraction in SHR resulted in a lower supply-dependent VO2 at low values of spinotrapezius DO2, perhaps attributed to arteriolar thickening and rarefaction seen in chronic hypertension.

Entities:  

Mesh:

Year:  2006        PMID: 16721270     DOI: 10.1097/01.shk.0000209548.14424.53

Source DB:  PubMed          Journal:  Shock        ISSN: 1073-2322            Impact factor:   3.454


  2 in total

1.  Photoacoustic Imaging for the Detection of Hypoxia in the Rat Femoral Artery and Skeletal Muscle Microcirculation.

Authors:  Lane M Smith; Jasmina Varagic; Liliya M Yamaleyeva
Journal:  Shock       Date:  2016-11       Impact factor: 3.454

2.  Wireless, battery-free optoelectronic systems as subdermal implants for local tissue oximetry.

Authors:  Hao Zhang; Philipp Gutruf; Kathleen Meacham; Michael C Montana; Xingyue Zhao; Antonio M Chiarelli; Abraham Vázquez-Guardado; Aaron Norris; Luyao Lu; Qinglei Guo; Chenkai Xu; Yixin Wu; Hangbo Zhao; Xin Ning; Wubin Bai; Irawati Kandela; Chad R Haney; Debashis Chanda; Robert W Gereau; John A Rogers
Journal:  Sci Adv       Date:  2019-03-08       Impact factor: 14.136

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.