Literature DB >> 16720687

Comparison of real-time tri-plane and conventional 2D dobutamine stress echocardiography for the assessment of coronary artery disease.

Elif Eroglu1, Jan D'hooge, Lieven Herbots, Daisy Thijs, Christophe Dubois, Peter Sinnaeve, Joseph Dens, Johan Vanhaecke, Frank Rademakers.   

Abstract

AIMS: Although dobutamine stress echocardiography (DSE) is an accepted tool for the diagnosis of coronary artery disease (CAD), it requires subsequent image acquisitions of the left ventricle (LV) in order to visualize all segments. This makes the procedure relatively time-consuming and might limit its accuracy. With the introduction of matrix array transducers, the real-time simultaneous acquisition of all LV segments has become possible using multi-plane imaging. The purpose of this study was: (i) to test the feasibility and efficiency of real-time tri-plane (RT3P) imaging during DSE, (ii) to compare the accuracy of RT3P DSE in detecting CAD using coronary angiography as the reference method. METHODS AND
RESULTS: Thirty-six patients suspected of CAD were prospectively enrolled. Both conventional two-dimensional (2D) and RT3P imaging were performed during a DSE protocol. Coronary angiography was performed within 24 h. Ultrasound data were acquired at each stage of the DSE. The total effective acquisition time for RT3P imaging was significantly shorter (55+/-29 vs. 137+/-63 s, P<0.001). Data yield was similar for both methods (2D: 98% vs. 3D: 97%). Overall sensitivity (93%), specificity (75%), and accuracy (89%) were identical between both methods. On a segmental level, the sensitivity, specificity, and accuracy of the RT3P and the 2D DSE were similar.
CONCLUSION: RT3P imaging fastens the DSE protocol without compromising the accuracy for the diagnosis of CAD. This could facilitate a more wide-spread use of DSE and therefore contributes positively to its routine clinical acceptance.

Entities:  

Mesh:

Year:  2006        PMID: 16720687     DOI: 10.1093/eurheartj/ehl023

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  4 in total

Review 1.  Stress echocardiography for the detection and assessment of coronary artery disease.

Authors:  Nowell M Fine; Patricia A Pellikka
Journal:  J Nucl Cardiol       Date:  2011-05       Impact factor: 5.952

2.  Feasibility of real-time three-dimensional stress echocardiography: pharmacological and semi-supine exercise.

Authors:  Lorenza Pratali; Sabrina Molinaro; Anca I Corciu; Emilio M Pasanisi; Marco Scalese; Rosa Sicari
Journal:  Cardiovasc Ultrasound       Date:  2010-03-24       Impact factor: 2.062

3.  Stress echocardiography in coronary artery disease: a practical guideline from the British Society of Echocardiography.

Authors:  Richard P Steeds; Richard Wheeler; Sanjeev Bhattacharyya; Joseph Reiken; Petros Nihoyannopoulos; Roxy Senior; Mark J Monaghan; Vishal Sharma
Journal:  Echo Res Pract       Date:  2019-06-01

4.  Head to head comparison of 2D vs real time 3D dipyridamole stress echocardiography.

Authors:  Silvia Varnero; Patricia Santagata; Lorenza Pratali; Massimiliano Basso; Alfredo Gandolfo; Paolo Bellotti
Journal:  Cardiovasc Ultrasound       Date:  2008-06-20       Impact factor: 2.062

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.