Literature DB >> 16717341

A systematic review (meta-analysis) of the accuracy of the Mallampati tests to predict the difficult airway.

Anna Lee1, Lawrence T Y Fan, Tony Gin, Manoj K Karmakar, Warwick D Ngan Kee.   

Abstract

The original and modified Mallampati tests are commonly used to predict the difficult airway, but there is controversy regarding their accuracy. We searched MEDLINE and other databases for prospective studies of patients undergoing general anesthesia in which the results of a preoperative Mallampati test were compared with the subsequent rate of difficult airway (difficult laryngoscopy, difficult intubation, or difficult ventilation as reference tests). Forty-two studies enrolling 34,513 patients were included. The definitions of the reference tests varied widely. For predicting difficult laryngoscopy, both versions of the Mallampati test had good accuracy (area under the summary receiver operating characteristic (sROC) curve = 0.89 +/- 0.05 and 0.78 +/- 0.05, respectively). For predicting difficult intubation, the modified Mallampati test had good accuracy (area under the sROC curve = 0.83 +/- 0.03) whereas the original Mallampati test was poor (area under the sROC curve = 0.58 +/- 0.12). The Mallampati tests were poor at identifying difficult mask ventilation. Publication bias was not detected. Used alone, the Mallampati tests have limited accuracy for predicting the difficult airway and thus are not useful screening tests.

Entities:  

Mesh:

Year:  2006        PMID: 16717341     DOI: 10.1213/01.ane.0000217211.12232.55

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  61 in total

Review 1.  [Airway management].

Authors:  G Schälte; S Rex; D Henzler
Journal:  Anaesthesist       Date:  2007-08       Impact factor: 1.041

2.  Prediction of difficult laryngoscopy using spirometry: a pilot study.

Authors:  Serkan Dogru; Tugba Karaman; Aynur Sahin; Hakan Tapar; Serkan Karaman; Semih Arici; Mustafa Suren; Ziya Kaya; Battal Tahsin Somuk
Journal:  J Clin Monit Comput       Date:  2016-11-19       Impact factor: 2.502

3.  Is the modified Mallampati test performed in supine position a reliable predictor of difficult tracheal intubation?

Authors:  Ashish Bindra; Hemanshu Prabhakar; Gyaninder Pal Singh; Zulfiqar Ali; Vasudha Singhal
Journal:  J Anesth       Date:  2010-03-10       Impact factor: 2.078

Review 4.  Ultrasonography in the preoperative difficult airway assessment.

Authors:  Justin S Fulkerson; Heather M Moore; Tristan S Anderson; Robert F Lowe
Journal:  J Clin Monit Comput       Date:  2016-05-07       Impact factor: 2.502

5.  The assessment of airway maneuvers and interventions in university Canadian football, ice hockey, and soccer players.

Authors:  J Scott Delaney; Ammar Al-Kashmiri; Penny-Jane Baylis; Tracy Troutman; Mahmood Aljufaili; José A Correa
Journal:  J Athl Train       Date:  2011 Mar-Apr       Impact factor: 2.860

6.  Chest anteroposterior diameter affects difficulty of laryngoscopy for non-morbidly obese patients.

Authors:  Ji-Won Choi; Jie-Ae Kim; Hae-Kyoung Kim; Min-Seok Oh; Duk-Kyung Kim
Journal:  J Anesth       Date:  2013-03-02       Impact factor: 2.078

7.  Masseter muscle rigidity: Atypical malignant hyperthermia presentation or isolated event?

Authors:  Tonia C U Onyeka
Journal:  Saudi J Anaesth       Date:  2010-09

8.  Hyomental distance in the different head positions and hyomental distance ratio in predicting difficult intubation.

Authors:  Nevena Kalezić; Mirko Lakićević; Biljana Miličić; Marina Stojanović; Vera Sabljak; Dejan Marković
Journal:  Bosn J Basic Med Sci       Date:  2016-06-14       Impact factor: 3.363

9.  How well do discrete choice experiments predict health choices? A systematic review and meta-analysis of external validity.

Authors:  Matthew Quaife; Fern Terris-Prestholt; Gian Luca Di Tanna; Peter Vickerman
Journal:  Eur J Health Econ       Date:  2018-01-29

10.  The videolaryngoscope is less traumatic than the classic laryngoscope for a difficult airway in an obese patient.

Authors:  Ralph Maassen; Ruben Lee; André van Zundert; Richard Cooper
Journal:  J Anesth       Date:  2009-08-14       Impact factor: 2.078

View more