A comparison of immediate postreduction splinting constructs for controlling initial displacement of fractures of the distal radius: a prospective randomized study of long-arm versus short-arm splinting.

Matthew R Bong1, Kenneth A Egol, Matthew Leibman, Kenneth J Koval.   

Abstract

PURPOSE: To compare, in a prospective, randomized manner, the sugar tong splint with a short-arm radial gutter splint in terms of patient satisfaction and the ability to maintain reduction of distal radius fractures.
METHODS: A total of 118 patients with displaced distal radius fractures were enrolled; 85 patients (85 fractures) were available for follow-up evaluation and were included in the study population. There were 26 men and 59 women with a mean age of 64 years. Thirty-eight fractures were immobilized in a short-arm radial gutter splint and 47 in a sugar tong splint. Forty fractures had a stable pattern and 45 had an unstable fracture pattern. The initial patient follow-up examination occurred a mean of 8 days after splint application.
RESULTS: A total of 33 fractures showed loss of fracture reduction at the initial follow-up evaluation. Sixteen of 38 fractures immobilized with the radial gutter splint displaced, whereas displacement was seen in 17 of 47 fractures immobilized with a sugar tong splint; this difference was not significant. When the splint constructs were evaluated based on fracture stability no differences were found between the splints' ability to maintain fracture reduction in both stable and unstable displaced fractures. Patients in the short-arm radial gutter splint group had significantly better Disabilities of the Arm, Shoulder, and Hand scores than those patients whose fractures were immobilized with a sugar tong splint.
CONCLUSIONS: Both the sugar tong splint and the short-arm radial gutter splint had comparable performance in maintaining the initial reduction of distal radius fractures, with the short-arm splint tolerated better by patients. Based on our study we recommend the use of a short-arm radial gutter splint for initial immobilization of displaced distal radius fractures. TYPE OF STUDY/LEVEL OF EVIDENCE: Prognostic, level II.

Entities:  

Mesh:

Year:  2006        PMID: 16713840     DOI: 10.1016/j.jhsa.2006.01.016

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  17 in total

1.  In regards to the article by Gamba et al.: "Which immobilization is better for distal radius fracture? A prospective randomized trial".

Authors:  Hang Li; Lei Yang
Journal:  Int Orthop       Date:  2017-07-28       Impact factor: 3.075

2.  Assessment of Forearm Rotational Control Using 4 Upper Extremity Immobilization Constructs.

Authors:  Ayesha M Rahman; Nicole Montero-Lopez; Richard M Hinds; Michael Gottschalk; Eitan Melamed; John T Capo
Journal:  Hand (N Y)       Date:  2017-02-02

Review 3.  Common myths and evidence in the management of distal radius fractures.

Authors:  Rafael J Diaz-Garcia; Kevin C Chung
Journal:  Hand Clin       Date:  2012-03-24       Impact factor: 1.907

4.  Adult Closed Distal Radius Fracture Reduction: Does Fluoroscopy Improve Alignment and Reduce Indications for Surgery?

Authors:  Efi Kazum; Assaf Kadar; Zachary T Sharfman; Hila Otremsky; Roy Gigi; Yishai Rosenblatt; Oleg Dolkart; Tamir Pritsch
Journal:  Hand (N Y)       Date:  2016-10-04

5.  Below- vs above-elbow cast for distal radius fractures: is elbow immobilization really effective for reduction maintenance?

Authors:  Tommaso Maluta; Giovanni Dib; Matteo Cengarle; Alice Bernasconi; Elena Samaila; Bruno Magnan
Journal:  Int Orthop       Date:  2018-10-15       Impact factor: 3.075

6.  Distal Radius Fractures Do Not Displace following Splint or Cast Removal in the Acute, Postreduction Period: A Prospective, Observational Study.

Authors:  Brock D Foster; Lakshmanan Sivasundaram; Nathanael Heckmann; William C Pannell; Ram K Alluri; Alidad Ghiassi
Journal:  J Wrist Surg       Date:  2016-08-31

7.  Which immobilization is better for distal radius fracture? A prospective randomized trial.

Authors:  Carlo Gamba; Felipe Andrés Mingo Fernandez; Marta Cuenca Llavall; Xavier Lizano Diez; Fernando Santana Perez
Journal:  Int Orthop       Date:  2017-06-03       Impact factor: 3.075

8.  Custom-made finger splint versus prefabricated finger splint: finger flexion stabilization.

Authors:  Enver Güven; Sinem Suner-Keklik
Journal:  Rev Assoc Med Bras (1992)       Date:  2022-07       Impact factor: 1.712

9.  Short arm cast is as effective as long arm cast in maintaining distal radius fracture reduction: Results of the SLA-VER noninferiority trial.

Authors:  Giovanni Dib; Tommaso Maluta; Matteo Cengarle; Alice Bernasconi; Giulia Marconato; Massimo Corain; Bruno Magnan
Journal:  World J Orthop       Date:  2022-09-18

10.  Immobilization following Distal Radius Fractures: A Randomized Clinical Trial.

Authors:  J Ryan Hill; Paul D Navo; Gabriel Bouz; Ali Azad; William Pannell; R Kiran Alluri; Alidad Ghiassi
Journal:  J Wrist Surg       Date:  2018-08-07