Literature DB >> 16712926

The effects of combined gentamicin-hydroxyapatite coating for cementless joint prostheses on the reduction of infection rates in a rabbit infection prophylaxis model.

Volker Alt1, Achim Bitschnau, Jana Osterling, Andreas Sewing, Christof Meyer, Ralf Kraus, Stefan A Meissner, Sabine Wenisch, Eugen Domann, Reinhard Schnettler.   

Abstract

Infections remain a critical issue in total joint arthroplasty. Addition of antibiotics to bone cement was shown to significantly improve antimicrobial prophylaxis in cemented joint arthroplasty. In cementless joint arthroplasty a comparable prophylaxis by local antibiotics has not been possible yet. The aim of the current study was to investigate the antimicrobial effect of two different gentamicin-hydroxyapatite (HA) coatings for cementless prostheses in a rabbit infection model. Staphylococcus aureus with a dose of 10(7) CFUs was inoculated into the intramedullary canal of the tibia of 30 rabbits followed by the implantation of standard steel HA K-wires (n=10), steel K-wires coated with a gentamicin-HA combination (n=10), and steel K-wires coated with a gentamicin-RGD-HA combination (n=10), respectively. The animals were sacrificed after 28 days and clinical, histological and microbiological assessment on the bone and on the removed K-wire itself by agar plating and DNA-pulsed field gel electrophoresis were carried out to detect infection. There was a statistically significant reduction of infection rates by both gentamicin-coating types (0 infections in both groups) compared to standard HA coating (7 infections in 8 animals; 2 animals were lost due to acute diarrhea) (p<0.001). An excellent correlation between agar plating testing results of the K-wires and of the bone samples was found. Detailed histology showed cortical lysis, abscess and sequester formation in the infected animals. Both gentamicin-coating types showed significant improvement of infection prophylaxis compared to standard HA coating and, therefore, this coating technology could help to improve infection prophylaxis in cementless total joint arthroplasty. In further studies biocompatibility of the coatings has to be assessed.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16712926     DOI: 10.1016/j.biomaterials.2006.04.035

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  36 in total

1.  [Collagen hydroxyapatite (Healos) saturated with gentamicin or levofloxacin. In vitro antimicrobial effectiveness - a pilot study].

Authors:  C H Fürstenberg; B Wiedenhöfer; C Putz; I Burckhardt; S Gantz; K Kleinschmidt; K Schröder
Journal:  Orthopade       Date:  2010-04       Impact factor: 1.087

Review 2.  Antimicrobial technology in orthopedic and spinal implants.

Authors:  Adam Em Eltorai; Jack Haglin; Sudheesha Perera; Bielinsky A Brea; Roy Ruttiman; Dioscaris R Garcia; Christopher T Born; Alan H Daniels
Journal:  World J Orthop       Date:  2016-06-18

3.  Nano-Ag-loaded hydroxyapatite coatings on titanium surfaces by electrochemical deposition.

Authors:  Xiong Lu; Bailin Zhang; Yingbo Wang; Xianli Zhou; Jie Weng; Shuxin Qu; Bo Feng; Fumio Watari; Yonghui Ding; Yang Leng
Journal:  J R Soc Interface       Date:  2010-09-29       Impact factor: 4.118

4.  Electrodeposited silk coatings for bone implants.

Authors:  Roberto Elia; Courtney D Michelson; Austin L Perera; Teresa F Brunner; Masly Harsono; Gray G Leisk; Gerard Kugel; David L Kaplan
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-12-24       Impact factor: 3.368

5.  Surface topography of silicon nitride affects antimicrobial and osseointegrative properties of tibial implants in a murine model.

Authors:  Masahiro Ishikawa; Karen L de Mesy Bentley; Bryan J McEntire; B Sonny Bal; Edward M Schwarz; Chao Xie
Journal:  J Biomed Mater Res A       Date:  2017-09-26       Impact factor: 4.396

6.  A mouse model of post-arthroplasty Staphylococcus aureus joint infection to evaluate in vivo the efficacy of antimicrobial implant coatings.

Authors:  Nicholas M Bernthal; Alexandra I Stavrakis; Fabrizio Billi; John S Cho; Thomas J Kremen; Scott I Simon; Ambrose L Cheung; Gerald A Finerman; Jay R Lieberman; John S Adams; Lloyd S Miller
Journal:  PLoS One       Date:  2010-09-07       Impact factor: 3.240

7.  Comprehensive evaluation of fibrin glue as a local drug-delivery system-efficacy and safety of sustained release of vancomycin by fibrin glue against local methicillin-resistant Staphylococcus aureus infection.

Authors:  Shinichi Ozaki; Aya Saito; Hidemasa Nakaminami; Minoru Ono; Norihisa Noguchi; Noboru Motomura
Journal:  J Artif Organs       Date:  2013-12-01       Impact factor: 1.731

Review 8.  The future of biologic coatings for orthopaedic implants.

Authors:  Stuart B Goodman; Zhenyu Yao; Michael Keeney; Fan Yang
Journal:  Biomaterials       Date:  2013-02-04       Impact factor: 12.479

9.  A silver ion-doped calcium phosphate-based ceramic nanopowder-coated prosthesis increased infection resistance.

Authors:  Nusret Kose; Ali Otuzbir; Ceren Pekşen; Abdurrahman Kiremitçi; Aydin Doğan
Journal:  Clin Orthop Relat Res       Date:  2013-08       Impact factor: 4.176

10.  In vivo effect of quaternized chitosan-loaded polymethylmethacrylate bone cement on methicillin-resistant Staphylococcus epidermidis infection of the tibial metaphysis in a rabbit model.

Authors:  Hong-Lue Tan; Hai-Yong Ao; Rui Ma; Wen-Tao Lin; Ting-Ting Tang
Journal:  Antimicrob Agents Chemother       Date:  2014-07-28       Impact factor: 5.191

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.