Literature DB >> 16711255

Optimization, comparison, and application of colorimetric vs. chemiluminescence based indirect sandwich ELISA for measurement of human IL-23.

Sridhar Samineni1, Sitaram Parvataneni, Caleb Kelly, Venu Gangur, Wilfried Karmaus, Kevin Brooks.   

Abstract

Currently, there is neither a published ELISA method nor it is clear whether chemiluminescence substrates would provide better sensitivity vs. colorimetric substrates for measuring human IL-23-a recently described Type-1 immunity associated cytokine. Initially, we optimized a colorimetric ELISA using p-nitro-phenyl phosphate substrate. Subsequently, we compared it with chemiluminescence substrates that provided approximately 5-fold enhanced sensitivity (mean sensitivity; 26.3 pg/mL vs. colorimetric assay, 131 pg/mL; p < 0.01). Both methods were reliable, with <10% inter- and intra-assay variations. We then found that the chemiluminescence method was useful in situations where human IL-23 was not readily measurable by a colorimetric method.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16711255     DOI: 10.1080/15321810600573051

Source DB:  PubMed          Journal:  J Immunoassay Immunochem        ISSN: 1532-1819


  5 in total

1.  A dendrimer-based immunosensor for improved capture and detection of tumor necrosis factor-α cytokine.

Authors:  Admira Bosnjakovic; Manoj K Mishra; Hye Jung Han; Roberto Romero; Rangaramanujam M Kannan
Journal:  Anal Chim Acta       Date:  2012-01-18       Impact factor: 6.558

2.  Rapid and Sensitive Colorimetric ELISA using Silver Nanoparticles, Microwaves and Split Ring Resonator Structures.

Authors:  Sarah A Addae; Melissa A Pinard; Humeyra Caglayan; Semih Cakmakyapan; Deniz Caliskan; Ekmel Ozbay; Kadir Aslan
Journal:  Nano Biomed Eng       Date:  2010-01-01

3.  Flu-like symptoms and associated immunological response following therapy with botulinum toxins.

Authors:  José Fidel Baizabal-Carvallo; Joseph Jankovic; Jordan Feld
Journal:  Neurotox Res       Date:  2013-05-16       Impact factor: 3.911

4.  Simultaneous multi-analyte urinary protein assay for bladder cancer detection.

Authors:  Charles J Rosser; Yunfeng Dai; Makito Miyake; Ge Zhang; Steve Goodison
Journal:  BMC Biotechnol       Date:  2014-04-01       Impact factor: 2.563

5.  Waning antibody levels after COVID-19 vaccination with mRNA Comirnaty and inactivated CoronaVac vaccines in blood donors, Hong Kong, April 2020 to October 2021.

Authors:  Shirley Ll Kwok; Samuel Ms Cheng; Jennifer Ns Leung; Kathy Leung; Cheuk-Kwong Lee; Js Malik Peiris; Joseph T Wu
Journal:  Euro Surveill       Date:  2022-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.