Literature DB >> 16710882

Three-dimensional ultrasound volume calculations of human embryos and young fetuses: a study on the volumetry of compound structures and its reproducibility.

H-G K Blaas1, P Taipale, H Torp, S H Eik-Nes.   

Abstract

OBJECTIVE: To evaluate volumetry with three-dimensional (3D) ultrasonography in the assessment of the size of human embryos and fetuses.
METHODS: Forty-four healthy embryos/fetuses with crown-rump length (CRL) ranging from 9 mm to 58 mm were studied using a 7.5-MHz annular array transvaginal 3D probe. EchoPAC 3D software was used to calculate the volumes of the head, body and limbs in the same data set by two observers working independently of each other. Regression analysis was used to assess the relationship between estimated volumes and CRL.
RESULTS: The embryonic and fetal volume estimates of both observers ranged from a mean of 93 mm3 at 10 mm CRL to a mean of 11 169 mm3 at 55 mm CRL. The volume of the limbs as a proportion of the mean whole-body volume increased from 4.7% at a CRL of 15 mm to 9.3% at a CRL of 55 mm. Limits of agreement between the observers were calculated to be -0.12 +/- 9.2%.
CONCLUSION: It is possible to reconstruct complex small anatomic structures and calculate the volumes of human embryos and fetuses in vivo by using dedicated 3D ultrasound equipment. The reproducibility of whole-body volume estimates seems to be high. The limbs represent a significant proportion of the size of the embryonic/fetal body. Copyright 2006 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2006        PMID: 16710882     DOI: 10.1002/uog.2794

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  6 in total

Review 1.  Gestation-Specific Changes in the Anatomy and Physiology of Healthy Pregnant Women: An Extended Repository of Model Parameters for Physiologically Based Pharmacokinetic Modeling in Pregnancy.

Authors:  André Dallmann; Ibrahim Ince; Michaela Meyer; Stefan Willmann; Thomas Eissing; Georg Hempel
Journal:  Clin Pharmacokinet       Date:  2017-11       Impact factor: 6.447

2.  Quantitative assessment of gestational sac shape: the gestational sac shape score.

Authors:  R L Deter; J Li; W Lee; S Liu; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2007-05       Impact factor: 7.299

3.  Fetal volume measurements with three dimensional ultrasound in the first trimester of pregnancy, related to pregnancy outcome, a prospective cohort study.

Authors:  Nicol A C Smeets; Marc Prudon; Bjorn Winkens; S Guid Oei
Journal:  BMC Pregnancy Childbirth       Date:  2012-05-28       Impact factor: 3.007

4.  Applicability of three-dimensional imaging techniques in fetal medicine.

Authors:  Heron Werner Júnior; Jorge Lopes Dos Santos; Simone Belmonte; Gerson Ribeiro; Pedro Daltro; Emerson Leandro Gasparetto; Edson Marchiori
Journal:  Radiol Bras       Date:  2016 Sep-Oct

Review 5.  Automated Techniques for the Interpretation of Fetal Abnormalities: A Review.

Authors:  Vidhi Rawat; Alok Jain; Vibhakar Shrimali
Journal:  Appl Bionics Biomech       Date:  2018-06-10       Impact factor: 1.781

6.  First trimester fetal proportion volumetric measurements using a Virtual Reality approach.

Authors:  Clarissa J Wiertsema; Jan S Erkamp; Annemarie G M G J Mulders; Eric A P Steegers; Liesbeth Duijts; Anton H J Koning; Romy Gaillard; Vincent W V Jaddoe
Journal:  Prenat Diagn       Date:  2021-05-03       Impact factor: 3.050

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.