Literature DB >> 16710632

Bone grafts impregnated with antibiotics as a tool for treating infected implants in orthopedic surgery - one stage revision results.

Heinz Winkler1, Karl Kaudela, Alexander Stoiber, Franz Menschik.   

Abstract

Infection of an orthopedic implant is considered a devastating complication, necessitating its complete removal and thorough debridement of the site. Osseous defects are common in such conditions and need to be addressed before a new implant may be inserted. So far bone grafting has been contraindicated in bacterially contaminated areas and could only be performed as soon as all signs of infection have ceased. Usually long term antibiotic treatment and a multitude of surgical interventions within a period of several months is required until a definitive supply can be achieved. Allograft bone may be impregnated with high loads of antibiotics using special incubation techniques. Based on this technology 48 exchange procedures of infected orthopaedic implants were performed in a single stage, all of them without the use of bone cement. There were 37 infected hips, 8 knees and 3 infected osteosyntheses. Two hips required re-revision because of persisting infection, the remaining 46 patients stayed infect free for a period between 1 and 7 years after surgery. No adverse side effects could be found. Incorporation appeared as after grafting with unimpregnated bone grafts. Antibiotic loaded allograft bone is a powerful tool in septic revision surgery, enabling restoration of bone stock, insertion of a new implant and control of infection in a single operation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16710632     DOI: 10.1007/s10561-006-9010-3

Source DB:  PubMed          Journal:  Cell Tissue Bank        ISSN: 1389-9333            Impact factor:   1.522


  20 in total

1.  Testing the efficacy of antimicrobial peptides in the topical treatment of induced osteomyelitis in rats.

Authors:  Pavel Melicherčík; Václav Čeřovský; Ondřej Nešuta; David Jahoda; Ivan Landor; Rastislav Ballay; Petr Fulín
Journal:  Folia Microbiol (Praha)       Date:  2017-08-02       Impact factor: 2.099

2.  Polymer-controlled release of tobramycin from bone graft void filler.

Authors:  Amanda E Brooks; Benjamin D Brooks; Sherry N Davidoff; Paul C Hogrebe; Mark A Fisher; David W Grainger
Journal:  Drug Deliv Transl Res       Date:  2013-12       Impact factor: 4.617

3.  Prevention of surgical site infections in bone and joint procedures.

Authors:  Ralf-Peter Vonberg; Petra Gastmeier
Journal:  Curr Infect Dis Rep       Date:  2012-10       Impact factor: 3.725

4.  Determination of antibacterial properties and cytocompatibility of silver-loaded coral hydroxyapatite.

Authors:  Yu Zhang; Qing-Shui Yin; Yu Zhang; Hong Xia; Fu-Zhi Ai; Yan-Peng Jiao; Xu-Qiong Chen
Journal:  J Mater Sci Mater Med       Date:  2010-06-05       Impact factor: 3.896

Review 5.  [Potential of allogeneic bone grafts as antibiotic carriers : Effect of different preparation processes on efficacy].

Authors:  D C Coraça-Huber; M Nogler; K-D Kühn
Journal:  Orthopade       Date:  2018-01       Impact factor: 1.087

6.  Impregnation of bone chips with antibiotics and storage of antibiotics at different temperatures: an in vitro study.

Authors:  Nina M C Mathijssen; Pieter L C Petit; Peter Pilot; B Wim Schreurs; Pieter Buma; Rolf M Bloem
Journal:  BMC Musculoskelet Disord       Date:  2010-05-25       Impact factor: 2.362

7.  Antibiotic modification of native grafts: improving upon nature's scaffolds.

Authors:  Constantinos Ketonis; Christopher S Adams; Stephanie Barr; Amiethab Aiyer; Irving M Shapiro; Javad Parvizi; Noreen J Hickok
Journal:  Tissue Eng Part A       Date:  2010-06       Impact factor: 3.845

8.  Antibiotic-impregnated bone grafts in orthopaedic and trauma surgery: a systematic review of the literature.

Authors:  Konstantinos Anagnostakos; Katrin Schröder
Journal:  Int J Biomater       Date:  2012-07-26

9.  Decal bone matrix as a local antibiotic delivery vehicle in a MRSA-infected bone model: An experimental study.

Authors:  Shyam K Saraf; Awadhesh Yadav; Santosh Nagwani; Mr Sen
Journal:  Indian J Orthop       Date:  2010-07       Impact factor: 1.251

10.  Trabecular metal acetabular revision system (cup-cage construct) to address the massive acetabular defects in revision arthroplasty.

Authors:  Rajesh Malhotra; Ramprasad Kancherla; Vijay Kumar; Aditya Soral
Journal:  Indian J Orthop       Date:  2012-07       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.