AIM: The anatomical accuracy of hardware-based registration of skeletal single photon emission computed tomography (SPECT) and X-ray computerized tomography (CT) has as yet not been studied. The aim of this study was to evaluate this variable in the lower spine for a newly introduced hybrid SPECT/spiral-CT camera.
METHODS: In 22 patients referred for degenerative joint disease or tumours, whole-body bone scintigraphy including hybrid SPECT/spiral CT of the lower spine was performed. Subsequent analyses were performed on these pairs of images as well as on data sets obtained after using a rigid automated fusion procedure in addition. Two observers independently measured the distances between the visually determined centres of gravity of the CT and SPECT representation of the fourth and fifth lumbar vertebral body in the X-, Y- and Z-directions (X-, Y- and Z-distances).
RESULTS: The distances determined by the two observers for the two vertebral bodies correlated significantly and were averaged for further analysis. For hybrid SPECT/spiral CT without consecutive automated registration, the mean X-, Y- and Z-distances were 1.6+/-1.9 mm, 1.7+/-1.3 mm and 0.9+/-0.5 mm, respectively. Additional automated registration lowered these values to 1.2+/-0.9 mm, 1.1+/-0.7 mm and 0.8+/-0.4 mm, respectively. The difference for the Y-distance proved statistically significant (P<0.05). Additional automated registration significantly reduced the number of subjects in whom at least one of the distances determined was greater than the SPECT pixel size of 4.6 mm from 14% (n=3) to 0% (P<0.05).
CONCLUSION: Hardware-based fusion between skeletal SPECT and CT offers a nearly perfect data match in the lower spine. The additional use of a tool for automated rigid registration has the potential to reduce the error of alignment even further and may be useful in patients with reduced compliance leading to movements between the two examinations.

Entities:  

Mesh:

Year:  2006        PMID: 16710107     DOI: 10.1097/00006231-200606000-00008

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  8 in total

1.  Single photon emission computerized tomography and conventional computerized tomography (SPECT/CT) for evaluation of patients after anterior cruciate ligament reconstruction: a novel standardized algorithm combining mechanical and metabolic information.

Authors:  Michael T Hirschmann; Dominic Mathis; Faik K Afifi; Helmut Rasch; Johann Henckel; Felix Amsler; Christopher R Wagner; Niklaus F Friederich; Markus P Arnold
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-13       Impact factor: 4.342

2.  Myocardial perfusion imaging with a novel SPECT/CT system: all that glitters is not gold.

Authors:  Jyrki T Kuikka
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-04       Impact factor: 9.236

3.  A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography.

Authors:  Michael T Hirschmann; Farhad Iranpour; Praveen Konala; Anna Kerner; Helmut Rasch; Justin P Cobb; Niklaus F Friederich
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-02-11       Impact factor: 4.342

Review 4.  Bone SPECT/CT in the postoperative spine: a focus on spinal fusion.

Authors:  Khulood Al-Riyami; Gopinath Gnanasegaran; Tim Van den Wyngaert; Jamshed Bomanji
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-07-05       Impact factor: 9.236

5.  Whole-body SPECT/CT for bone scintigraphy: diagnostic value and effect on patient management in oncological patients.

Authors:  H Palmedo; C Marx; A Ebert; B Kreft; Y Ko; A Türler; R Vorreuther; U Göhring; H H Schild; T Gerhardt; U Pöge; S Ezziddin; H-J Biersack; H Ahmadzadehfar
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-08-24       Impact factor: 9.236

6.  Evaluation of diagnosis techniques used for spinal injury related back pain.

Authors:  Meaghan Janssen; Aliaa Nabih; Walied Moussa; Gregory N Kawchuk; Jason P Carey
Journal:  Pain Res Treat       Date:  2011-06-13

7.  Shear wave elastography: a new noninvasive tool to assess the intensity of fibrosis of irradiated salivary glands in head and neck cancer patients.

Authors:  Jarosław Kałużny; Tomasz Kopeć; Ewelina Szczepanek-Parulska; Adam Stangierski; Edyta Gurgul; Marek Ruchała; Piotr Milecki; Małgorzata Wierzbicka
Journal:  Biomed Res Int       Date:  2014-08-17       Impact factor: 3.411

8.  Assessment of Inter-modality Spatial Alignment Accuracy in Hybrid Single Photon Emission Computed Tomography in Patients with Hand and Wrist Pain.

Authors:  Cheng Xie; Gopinath Gnanasegaran; Hosahalli Mohan; Lefteris Livieratos
Journal:  World J Nucl Med       Date:  2013-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.