Literature DB >> 16709467

First LC-MS/MS electrospray ionization validated method for the quantification of perindopril and its metabolite perindoprilat in human plasma and its application to bioequivalence study.

Deepak S Jain1, Gunta Subbaiah, Mallika Sanyal, Umesh C Pande, Pranav Shrivastav.   

Abstract

A high throughput bioanalytical method based on solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS), has been developed for the estimation of perindopril and its metabolite perindoprilat, an angiotensin-converting enzyme inhibitor in human plasma. Ramipril was used as internal standard (IS). The extraction of perindopril, perindoprilat and ramipril from the plasma involved treatment with phosphoric acid followed by solid phase extraction (SPE) using hydrophilic lipophilic balance HLB cartridge. The SPE eluate without drying were analyzed by LC-MS/MS, equipped with turbo ion spray (TIS) source, operating in the negative ion and selective reaction monitoring (SRM) acquisition mode to quantify perindopril and perindoprilat in human plasma. The total chromatographic run time was 1.5 min with retention time for perindopril, perindoprilat and ramipril at 0.33, 0.35 and 0.30 min. The developed method was validated in human plasma matrix, with a sensitivity of 0.5 ng/ml (CV, 7.67%) for perindopril and 0.3 ng/ml (CV, 4.94%) for perindoprilat. This method was extensively validated for its accuracy, precision, recovery, stability studies and matrix effect especially because the pattern of elution of all the analytes appears as flow injection elution. Sample preparation by this method yielded extremely clean extracts with very good and consistent mean recoveries; 78.29% for perindopril, 76.32% for perindoprilat and 77.72% for IS. The response of the LC-MS/MS method for perindopril and perindoprilat was linear over the range 0.5-350.0 ng/ml for perindopril and 0.3-40 ng/ml for perindoprilat with correlation coefficient, r>/=0.9998 and 0.9996, respectively. The method was successfully applied for bioequivalence studies in human subjects samples with 4 mg immediate release (IR) formulations.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16709467     DOI: 10.1016/j.jchromb.2006.04.008

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Novel Spectrofluorimetric Method for the Determination of Perindopril Erbumine Based on Fluorescence Quenching of Rhodamine B.

Authors:  Hanan Fael; Amir Al-Haj Sakur
Journal:  J Fluoresc       Date:  2015-10-05       Impact factor: 2.217

2.  Novel Spectrofluorimetric Method for the Determination of Perindopril Erbumine Based on Charge Transfer Reaction with 7-Hydroxycoumarin.

Authors:  Hanan Fael; Amir Al-Haj Sakur
Journal:  J Fluoresc       Date:  2015-07-07       Impact factor: 2.217

3.  CES1 genetic variation affects the activation of angiotensin-converting enzyme inhibitors.

Authors:  X Wang; G Wang; J Shi; J Aa; R Comas; Y Liang; H-J Zhu
Journal:  Pharmacogenomics J       Date:  2015-06-16       Impact factor: 3.550

4.  Simultaneous determination of indapamide, perindopril and perindoprilat in human plasma or whole blood by UPLC-MS/MS and its pharmacokinetic application.

Authors:  Yi Tao; Sheng Wang; Lei Wang; Min Song; Taijun Hang
Journal:  J Pharm Anal       Date:  2018-05-19
  4 in total