Literature DB >> 16705259

Reliability and sensitivity of jerk-cost measurement for evaluating irregularity of chewing jaw movements.

Kenji Takada1, Kohtaro Yashiro, Masato Takagi.   

Abstract

Rate of change in movement acceleration (jerk) is a universally accepted quantity to evaluate irregularities of human limb and eye movements. This study was aimed to attest reliability of the jerk measurement of masticatory jaw movements and to identify its sensitivity to discriminate between movements performed with the presence of varied occlusal interference. Jaw movements during gum chewing were recorded with a 3D tracking device. Twelve adult subjects participated in the experiments. For five subjects, normalized jerk-costs (NJC) during jaw closing were compared between those measured on two separate occasions. For seven subjects, the NJCs during closing were compared with those measured with/without introduction of four different types of occlusal interference. The NJCs did not differ significantly between the two recording occasions. The interference at the canine tooth induced greater increase in the NJCs than that at the molar tooth. The comparison between repeated measures revealed reproducibility of the NJCs. In addition, the NJC was shown to be capable of discriminating between irregularities of the movements induced by occlusal interference at the canine and molar tooth sites. These findings suggest that the NJC is a valid indicator of masticatory jaw movement irregularity induced by disturbances of full intercuspation between upper and lower teeth.

Entities:  

Mesh:

Year:  2006        PMID: 16705259     DOI: 10.1088/0967-3334/27/7/005

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  10 in total

1.  Development of force-based metrics for skills assessment in minimally invasive surgery.

Authors:  Ana Luisa Trejos; Rajni V Patel; Richard A Malthaner; Christopher M Schlachta
Journal:  Surg Endosc       Date:  2014-02-12       Impact factor: 4.584

2.  Speed-Accuracy Trade-Off in a Trajectory-Constrained Self-Feeding Task: A Quantitative Index of Unsuppressed Motor Noise in Children With Dystonia.

Authors:  Francesca Lunardini; Matteo Bertucco; Claudia Casellato; Nasir Bhanpuri; Alessandra Pedrocchi; Terence D Sanger
Journal:  J Child Neurol       Date:  2015-04-20       Impact factor: 1.987

3.  Children With and Without Dystonia Share Common Muscle Synergies While Performing Writing Tasks.

Authors:  Francesca Lunardini; Claudia Casellato; Matteo Bertucco; Terence D Sanger; Alessandra Pedrocchi
Journal:  Ann Biomed Eng       Date:  2017-05-30       Impact factor: 3.934

4.  Sensitivity of smoothness measures to movement duration, amplitude, and arrests.

Authors:  Neville Hogan; Dagmar Sternad
Journal:  J Mot Behav       Date:  2009-11       Impact factor: 1.328

5.  Performance and Capability Assessment in Surgical Subtask Automation.

Authors:  Tamás D Nagy; Tamás Haidegger
Journal:  Sensors (Basel)       Date:  2022-03-24       Impact factor: 3.576

6.  Assessing Smoothness of Arm Movements With Jerk: A Comparison of Laterality, Contraction Mode and Plane of Elevation. A Pilot Study.

Authors:  Alexandra Roren; Antoine Mazarguil; Diego Vaquero-Ramos; Jean-Baptiste Deloose; Pierre-Paul Vidal; Christelle Nguyen; François Rannou; Danping Wang; Laurent Oudre; Marie-Martine Lefèvre-Colau
Journal:  Front Bioeng Biotechnol       Date:  2022-01-21

7.  Shoulder motor performance assessment in the sagittal plane in children with hemiplegia during single joint pointing tasks.

Authors:  Domenico Formica; Maurizio Petrarca; Stefano Rossi; Loredana Zollo; Eugenio Guglielmelli; Paolo Cappa
Journal:  Biomed Eng Online       Date:  2014-07-29       Impact factor: 2.819

8.  The Dimensionless Squared Jerk: An Objective Parameter That Improves Assessment of Hand Motion Analysis during Simulated Shoulder Arthroscopy.

Authors:  Erica Kholinne; Maulik J Gandhi; Arnold Adikrishna; Hanpyo Hong; Haewon Kim; Jaesung Hong; In-Ho Jeon
Journal:  Biomed Res Int       Date:  2018-07-11       Impact factor: 3.411

9.  Analysis of Visuo Motor Control between Dominant Hand and Non-Dominant Hand for Effective Human-Robot Collaboration.

Authors:  Hanjin Jo; Woong Choi; Geonhui Lee; Wookhyun Park; Jaehyo Kim
Journal:  Sensors (Basel)       Date:  2020-11-08       Impact factor: 3.576

10.  Dimensionless squared jerk: An objective differential to assess experienced and novice probe movement in obstetric ultrasound.

Authors:  Brian P Dromey; Shahanaz Ahmed; Francisco Vasconcelos; Evangelos Mazomenos; Yada Kunpalin; Sebastien Ourselin; Jan Deprest; Anna L David; Danail Stoyanov; Donald M Peebles
Journal:  Prenat Diagn       Date:  2020-11-05       Impact factor: 3.242

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.