| Literature DB >> 16704806 |
Brendan Flannery1, Lisa B Gelling, Duc J Vugia, June M Weintraub, James J Salerno, Michael J Conroy, Valerie A Stevens, Charles E Rose, Matthew R Moore, Barry S Fields, Richard E Besser.
Abstract
Monochloramine disinfection of municipal water supplies is associated with decreased risk for Legionnaires' disease. We conducted a 2-year, prospective, environmental study to evaluate whether converting from chlorine to monochloramine for water disinfection would decrease Legionella colonization of hot water systems. Water and biofilm samples from 53 buildings were collected for Legionella culture during 6 intervals. Prevalence ratios (PRs) comparing Legionella colonization before and after monochloramine disinfection were adjusted for water system characteristics. Legionella colonized 60% of the hot water systems before monochloramine versus 4% after conversion (PR 0.07, 95% confidence interval 0.03-0.16). The median number of colonized sites per building decreased with monochloramine disinfection. Increased prevalence of Legionella colonization was associated with water heater temperatures <50 degrees C, buildings taller than 10 stories, and interruptions in water service. Increasing use of monochloramine in water supplies throughout the United States may reduce Legionella transmission and incidence of Legionnaires' disease.Entities:
Mesh:
Substances:
Year: 2006 PMID: 16704806 PMCID: PMC3294698 DOI: 10.3201/eid1204.051101
Source DB: PubMed Journal: Emerg Infect Dis ISSN: 1080-6040 Impact factor: 6.883
Characteristics of treated water in the city distribution system or in water heaters in 53 sampled buildings, San Francisco, California, stratified by year
| Measurement (unit)* | 2003, mean (range) | 2004,† mean (range) | Reference value‡ |
|---|---|---|---|
| Treated water | |||
| Total chlorine, ppm | 0.60 (0.01–2.20) | 1.97 (0.15–3.40) | 4.00 |
| Total trihalomethanes, ppb | 65.3 (16.0–143.0) | 34.8 (11.0–46.0) | 80.0 |
| Total haloacetic acids, ppb | 19.5 (6.0–55.0) | 20.3 (3.0–33.0) | 60.0 |
| Total organic carbon, ppb | 2.8 (2.4–3.3) | 2.9 (2.6–3.1) | NA |
| pH | 9.0 (7.4–9.9) | 8.8 (7.5–10.5) | NA |
| Lead, ppb§ | 6.7§ | 11.5 | 15.0 |
| Copper, ppb§ | 120§ | 90 | 1,300 |
| Water sampled from water heaters in 53 buildings¶ | |||
| Total chlorine, ppm | 0.13 (0–0.86) | 1.10 (0–2.20) | NA |
| Temperature, °C | 44.9 (17.8–87.8) | 45.1 (17.8–79.4) | NA |
| pH | 8.9 (7.5–10.5) | 8.7 (7.5–10.4) | NA |
*ppm, parts per million; ppb, parts per billion. †Measurements were taken from March through December 2004, after conversion to chloramine for residual disinfection. ‡Maximum allowable levels for compliance with Environmental Protection Agency standards. NA, not applicable. §Measurements for lead and copper are the 90th percentile for samples collected from point of use. Prechloramine samples were collected during 2001. ¶Water heater samples were collected on 3 occasions over a 10-month period. Mean and range were calculated for 159 samples.
Prevalence of Legionella colonization and concentrations in hot water systems in buildings in San Francisco, California, by residual disinfectant and sampling interval*
| Water source | Chlorine (2003) | Chloramine (2004) | ||||||
|---|---|---|---|---|---|---|---|---|
| Jan–May | Jun–Jul | Oct–Dec | Mar–May | Jun–Aug | Sep–Dec | p value† | ||
| Building water systems (n = 53) | ||||||||
| No. colonized with | 27 (51) | 34 (64) | 35 (66) | 5 (9) | 0 | 2 (4) | <0.001 | |
| Median no. | 3 (1–9) | 3 (1–8) | 4 (1–8) | 1 (1–4) | – | 1 (1–2) | 0.007 | |
| Water heaters (n = 53) | ||||||||
| No. colonized with | 12 (23) | 16 (30) | 17 (33) | 1 (2) | 0 | 0 | <0.001 | |
| Median | 200 (40–400) | 40 (10–500) | 20 (10–5,000) | 10 | – | – | 0.17 | |
| Point-of-use outlets (n = 212) | ||||||||
| No. colonized with | 75 (37) | 85 (41) | 86 (41) | 7 (3) | 0 | 2 (1) | <0.001 | |
| Median | 2.5 (0.05–25.0) | 1.5 (0.05–25.0) | 1.0 (0.05–25.0) | 0.05 (0.05–0.40) | – | 0.18 (0.10–0.25) | <0.001 | |
*Percentages calculated based on number of samples included in analyses (see Methods). †For Wilcoxon rank sum test comparing number of sites colonized with Legionella spp. before and after the conversion to chloramine disinfectant. ‡Includes only Legionella-positive sites.
FigureLegionella colonization of water heaters and point-of-use outlets sampled during 6 rounds of environmental sampling in buildings, San Francisco, California (in rows), by residual disinfectant and sampling interval. Legionella species or serogroups of Legionella pneumophila are represented with different colors. Each row represents a single building and each cell represents the results of Legionella culture for a site within the building. H, water heater; P, point-of-use outlet.
Factors associated with Legionella colonization of water heaters in sampled buildings, San Francisco, California
| Factor | No. samples | % | Adjusted prevalence ratio (95% CI)* | p value |
|---|---|---|---|---|
| Residual disinfectant | ||||
| Chlorine | 157 | 29 | Referent | |
| Chloramine | 159 | 1 | 0.04 (0.01–0.21) | <0.001 |
| Water heater temperature, °C | ||||
| <30 | 29 | 21 | Referent | |
| 30–39 | 68 | 24 | 0.43 (0.27–0.70) | 0.001 |
| 40–49 | 131 | 18 | 0.27 (0.16–0.46) | 0.001 |
| >50 | 88 | 1 | 0.09 (0.05–0.18) | 0.001 |
| Building height (stories) | ||||
| 3–10 | 215 | 11 | Referent | |
| >10 | 101 | 24 | 2.96 (1.51–5.79) | 0.002 |
| Disruption in service in last 3 mo | ||||
| Yes | 39 | 26 | 2.26 (1.31–3.88) | 0.003 |
| No | 277 | 13 | Referent | |
*Prevalence ratios and 95% confidence intervals (CIs) were adjusted for repeated sampling and for effects of all other variables.
Factors associated with Legionella colonization at point-of-use outlets in sampled buildings, San Francisco, California
| Factor | No. samples | % | Adjusted prevalence ratio (95% CI)* | p value |
|---|---|---|---|---|
| Residual disinfectant | ||||
| Chlorine | 617 | 39 | Referent | |
| Chloramine | 627 | 1 | 0.04 (0.02–0.09) | <0.001 |
| Water heater colonized with | ||||
| Yes | 182 | 74 | 1.74 (1.26–2.40) | <0.001 |
| No | 1,062 | 11 | Referent | |
| Temperature of water at point-of-use outlet, °C | ||||
| <30 | 23 | 13 | Referent | |
| 30–39 | 268 | 24 | 0.90 (0.39–2.08) | 0.8 |
| 40–49 | 786 | 22 | 0.85 (0.35–2.05) | 0.7 |
| >50 | 175 | 10 | 0.75 (0.29–1.90) | 0.5 |
| Building height (stories) | ||||
| 3–10 | 855 | 15 | Referent | |
| >10 | 397 | 31 | 1.85 (1.46–2.35) | <0.001 |
| Disruption in service in last 3 mo | ||||
| Yes | 142 | 23 | 1.34 (0.99–1.81) | 0.06 |
| No | 1,109 | 20 | Referent | |
*Prevalence ratios and 95% confidence intervals (CIs) were adjusted for repeated sampling and correlations between samples taken from the same building and for the effects of all other variables. Twenty-eight observations were missing.