Literature DB >> 16704696

Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, SITA Standard and SITA Fast perimetry in perimetrically inexperienced individuals.

Paulo de Tarso Ponte Pierre-Filho1, Rui Barroso Schimiti, José Paulo Cabral de Vasconcellos, Vital Paulino Costa.   

Abstract

PURPOSE: To evaluate the sensitivity and specificity of the screening modes of frequency-doubling technology (FDT), tendency-oriented perimetry (TOP), SITA Standard (SS) and SITA Fast (SF) in perimetrically inexperienced individuals.
METHODS: One eye of 64 glaucoma patients and 53 normal subjects who had never undergone automated perimetry were tested with programs C-20-5 (FDT), G1 (TOP) and 24-2 (SS and SF). The gold standard for glaucoma was the presence of a typical glaucomatous optic disc appearance on stereoscopic examination (judged by a glaucoma expert), and intraocular pressure (IOP) > 21 mmHg. The test order among strategies was randomized for each subject. To define an abnormal visual field, we applied three criteria for SS and SF and two criteria for TOP and FDT, all of which have been previously described in the literature. Sensitivities and specificities among the different criteria were compared using the Cochran test.
RESULTS: Frequency-doubling technology showed the shortest mean test duration, followed by TOP, SF and SS (p < 0.05). Sensitivity ranges were 87.5-89.1% for SS, 92.2-93.8% for SF, 87.5-89.1% for TOP, and 82.8-85.9% for FDT (p = 0.34). Specificity ranges were 73.6-83% for FDT, 56.6-62.3% for TOP, 60.4-69.8% for SF and 66.0-71.7% for SS. The specificity obtained with criterion 2 for FDT (based on the presence of two or more abnormal locations regardless of the severity of abnormal points) was higher than those measured with the other strategies (p < 0.01).
CONCLUSION: When testing individuals with no perimetric experience, moderate sensitivities and specificities should be expected, regardless of the strategy chosen.

Entities:  

Mesh:

Year:  2006        PMID: 16704696     DOI: 10.1111/j.1600-0420.2006.00639.x

Source DB:  PubMed          Journal:  Acta Ophthalmol Scand        ISSN: 1395-3907


  9 in total

1.  Comparative Analysis of Visual Field Plotting by Octopus Interzeag 1-2-3, Humphrey Field Analyser II and Frequency Doubling Perimetry in Glaucoma Patients in South Indian Population.

Authors:  A R Rajalakshmi; Elangovan Suma; D Ranjit Prabhu
Journal:  J Clin Diagn Res       Date:  2015-07-01

2.  Pattern noise (PANO): a new automated functional glaucoma test.

Authors:  Sylvain El-Khoury; Thomas Hannen; Diana Carmen Dragnea; Faustin Ngounou; Paul-Rolf Preußner
Journal:  Int Ophthalmol       Date:  2017-08-16       Impact factor: 2.031

3.  Diagnostic ability of Humphrey perimetry, Octopus perimetry, and optical coherence tomography for glaucomatous optic neuropathy.

Authors:  B Monsalve; A Ferreras; P Calvo; J A Urcola; M Figus; J Monsalve; P Frezzotti
Journal:  Eye (Lond)       Date:  2016-11-11       Impact factor: 3.775

4.  Glaucoma and mortality risk: findings from a prospective population-based study.

Authors:  Tilman Kühn; Sabine Rohrmann; Nena Karavasiloglou; David S Friedman; Aedin Cassidy; Till Bärnighausen; Alexander K Schuster; Stefan Nickels
Journal:  Sci Rep       Date:  2021-06-03       Impact factor: 4.379

5.  Prevalence of Glaucoma in the United States: The 2005-2008 National Health and Nutrition Examination Survey.

Authors:  Priya Gupta; Di Zhao; Eliseo Guallar; Fang Ko; Michael V Boland; David S Friedman
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-05-01       Impact factor: 4.799

6.  Cost and detection rate of glaucoma screening with imaging devices in a primary care center.

Authors:  Alfonso Anton; Monica Fallon; Francesc Cots; María A Sebastian; Antonio Morilla-Grasa; Sergi Mojal; Xavier Castells
Journal:  Clin Ophthalmol       Date:  2017-02-16

7.  Comparison of Advanced Threshold and SITA Fast Perimetric Strategies.

Authors:  Bartosz L Sikorski; Adriana Laudencka
Journal:  J Ophthalmol       Date:  2020-12-23       Impact factor: 1.909

8.  Comparative Study Between the SORS and Dynamic Strategy Visual Field Testing Methods on Glaucomatous and Healthy Subjects.

Authors:  Şerife Seda Kucur; Sebastian Häckel; Jan Stapelfeldt; Jeannine Odermatt; Milko E Iliev; Mathias Abegg; Raphael Sznitman; Rene Höhn
Journal:  Transl Vis Sci Technol       Date:  2020-12-02       Impact factor: 3.283

9.  Persistence, spatial distribution and implications for progression detection of blind parts of the visual field in glaucoma: a clinical cohort study.

Authors:  Francisco G Junoy Montolio; Christiaan Wesselink; Nomdo M Jansonius
Journal:  PLoS One       Date:  2012-07-27       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.