Bone ingrowths to press-fit and loose-fit implants: comparisons between titanium and hydroxyapatite.

Olav Reikerås1, Carina B Johansson, Mikael Sundfeldt.   

Abstract

The aim of this study was to investigate whether the coating of titanium (Ti) implants with hydroxyapatite (HA) might create a better fixation when titanium implants are implanted into a gap. In each of 16 rats, the medullary cavity of both femurs was entered by an awl from the trochanteric area. With steel burrs it was successively reamed to a diameter of 1.5 mm. In a random manner the proximal part of the cavity in half of the bones was reamed once again to a diameter of 2.0 mm. Nails with a diameter of 1.5 mm and a length of 34 mm were then inserted into the medullary cavity of these bones with press fit at the distal half and a gap to the bone in the proximal half. In the remaining bones the whole medullary canal was reamed to a diameter of 2.0 mm, and nails with a diameter of 2.0 mm and a length of 34 mm were introduced. In all cases, either a pure Ti nail or a Ti nail entirely plasma sprayed with HA was used in a random manner. The surface roughness of the pure Ti was characterized by Ra 2.6 microm and Rt 22 microm. Ra of HA was 7.5 microm and Rt 52 microm. At sacrifice after 16 weeks, both femurs were dissected free from soft tissues and then immersed in fixative. A specimen slice of about 5 mm in thickness was prepared from the subtrochanteric region with a water-cooled band saw. Sample preparation for undecalcified tissue followed the internal guidelines at the laboratories of the Department of Biomaterials/Handicap Research. Generally, bone contact to the nails with HA coating was more predictable than was bone contact to the Ti nails. But due to rather large variations in bone contact between the samples, statistical analyses revealed non-significant differences between the 4 groups (p = 0.083). There were no significant differences between Ti and HA coated nails of 2.0 mm (p = 0.633), nor between Ti and HA coated nails of 1.5 mm (p = 0.924). The pooled values for the 2.0 mm nails showed significantly higher bone bonding contact than the pooled values of the 1.5 mm nails (p = 0.011). Our results, then, indicate that bone bonding contact to implants with a loose fit insertion is less predictable than in press fit insertion, and HA coating seemed to be more predictable than pure Ti. However, due to large variations between the samples, the differences did not reach significant levels.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16700655     DOI: 10.1615/jlongtermeffmedimplants.v16.i2.40

Source DB:  PubMed          Journal:  J Long Term Eff Med Implants        ISSN: 1050-6934


  4 in total

Review 1.  Calcium Orthophosphate-Based Bioceramics.

Authors:  Sergey V Dorozhkin
Journal:  Materials (Basel)       Date:  2013-09-06       Impact factor: 3.623

2.  Calcium orthophosphates as bioceramics: state of the art.

Authors:  Sergey V Dorozhkin
Journal:  J Funct Biomater       Date:  2010-11-30

3.  Short to Midterm Follow-Up of Periprosthetic Bone Mineral Density after Total Hip Arthroplasty with the Ribbed Anatomic Stem.

Authors:  Xiang-Dong Wu; Mian Tian; Yao He; Hong Chen; Yu Chen; Rahul Mishra; Wei Liu; Wei Huang
Journal:  Biomed Res Int       Date:  2019-06-27       Impact factor: 3.411

Review 4.  Fabrication, Properties and Applications of Dense Hydroxyapatite: A Review.

Authors:  Mythili Prakasam; Janis Locs; Kristine Salma-Ancane; Dagnija Loca; Alain Largeteau; Liga Berzina-Cimdina
Journal:  J Funct Biomater       Date:  2015-12-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.