Alarms and human behaviour: implications for medical alarms.

J Edworthy1, E Hellier.   

Abstract

Alarms are used in many clinical applications, but they are often less than optimal because the design and implementation of alarms has not always taken the cognitive capacity and processing mechanisms of the user into account. As a result alarms are frequently too loud, irritating, confusing, badly designed, and too numerous, resulting in them often being turned off and hindering, rather than enhancing, task performance. This paper reviews some of the main areas where it is essential to take account of the cognitive system of the user and behavioural processes more generally. Five central areas of concern are discussed: the number of alarms and ways that this might be reduced; false alarm rates and their impact on human responses; the design of alarms and the application of research into auditory cognition on design; intelligent alarm systems; and the proposals for alarm design set out in a recent worldwide medical alarms standard. In each area some background is given and the implications for alarm design and implementation outlined. The conclusion is that there are some indications that alarm design and implementation takes account of relevant research data, but that there is still some way to go before these findings are fully integrated and the situation is improved upon further.

Entities:  

Mesh:

Year:  2006        PMID: 16698858     DOI: 10.1093/bja/ael114

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  18 in total

Review 1.  What's all that noise-Improving the hospital soundscape.

Authors:  Anthony J Oleksy; Joseph J Schlesinger
Journal:  J Clin Monit Comput       Date:  2018-11-02       Impact factor: 2.502

2.  Auditory display for fluorescence-guided open brain tumor surgery.

Authors:  David Black; Horst K Hahn; Ron Kikinis; Karin Wårdell; Neda Haj-Hosseini
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-09-19       Impact factor: 2.924

3.  Organizing Audible Alarm Sounds in the Hospital: A Card-Sorting Study.

Authors:  Melanie C Wright; Sydney Radcliffe; Suzanne Janzen; Judy Edworthy; Thomas Reese; Noa Segall
Journal:  IEEE Trans Hum Mach Syst       Date:  2020-09-14       Impact factor: 2.968

4.  An inherently dangerous fluid warmer design.

Authors:  Karolina Brook; Mark J Facchin; Albert A Kalustian; R Mauricio Gonzalez; Keegan L McDonnell; Donald H Lambert
Journal:  J Clin Monit Comput       Date:  2021-12-03       Impact factor: 1.977

5.  Designing informative warning signals: Effects of indicator type, modality, and task demand on recognition speed and accuracy.

Authors:  Catherine J Stevens; David Brennan; Agnes Petocz; Clare Howell
Journal:  Adv Cogn Psychol       Date:  2009-05-04

6.  SMART--an integrated wireless system for monitoring unattended patients.

Authors:  Dorothy W Curtis; Esteban J Pino; Jacob M Bailey; Eugene I Shih; Jason Waterman; Staal A Vinterbo; Thomas O Stair; John V Guttag; Robert A Greenes; Lucila Ohno-Machado
Journal:  J Am Med Inform Assoc       Date:  2007-10-18       Impact factor: 4.497

7.  Physiologic Monitor Alarm Rates at 5 Children's Hospitals.

Authors:  Amanda C Schondelmeyer; Patrick W Brady; Veena V Goel; Maria Cvach; Nancy Blake; Colleen Mangeot; Christopher P Bonafide
Journal:  J Hosp Med       Date:  2018-04-25       Impact factor: 2.960

8.  Designing the Vocal Alarm and improving medical ventilator.

Authors:  Soheila Mojdeh; Alireza Sadri; Mohammadmehdi Nabii; Hossein Emadian; Mojtaba Rahimi
Journal:  Iran J Nurs Midwifery Res       Date:  2011

9.  Clinical Alarms in Intensive Care Units: Perceived Obstacles of Alarm Management and Alarm Fatigue in Nurses.

Authors:  Ok Min Cho; Hwasoon Kim; Young Whee Lee; Insook Cho
Journal:  Healthc Inform Res       Date:  2016-01-31

Review 10.  Non-Invasive Continuous Respiratory Monitoring on General Hospital Wards: A Systematic Review.

Authors:  Kim van Loon; Bas van Zaane; Els J Bosch; Cor J Kalkman; Linda M Peelen
Journal:  PLoS One       Date:  2015-12-14       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.