Literature DB >> 16698482

Characterizing pseudoexfoliation syndrome through the use of ultrasound biomicroscopy.

Suqin Guo1, Matthew Gewirtz, Rajesh Thaker, Matthew Reed.   

Abstract

PURPOSE: To determine the clinical utility of ultrasound biomicroscopy (UBM) in diagnosis of pseudoexfoliation (PEX) syndrome by characterizing the lens capsule and zonules before cataract surgery.
SETTING: Veterans Administration Hospital, East Orange, and University of Medicine & Dentistry of New Jersey-New Jersey Medical School, Newark, New Jersey, USA.
METHODS: Ultrasound biomicroscopy was performed on 10 patients clinically diagnosed with PEX syndrome. The clinical diagnosis was made by the presence of fibrillin deposits on the anterior lens capsule, lack of pigment at the pupillary ruff, and poor pharmacologic dilation. Five persons without PEX were used as controls. The thickness of the anterior lens capsule was measured in 5 locations in each eye: centrally and in the peripheral lens capsule superiorly, inferiorly, nasally, and temporally. Four measurements were taken from the zonule at the thickest point on each fiber. The UBM also found the presence or absence of nodular deposits on the zonules.
RESULTS: The anterior and peripheral lens capsule in patients with PEX was thicker than that in the control group. Additionally, patients with PEX had thicker zonules than the control group and had nodular deposits present; the control group had no deposits. These differences were all significant with a 99% confidence interval.
CONCLUSIONS: A thicker anterior lens capsule and lens zonule nodules were associated with PEX. These abnormalities can be visualized with the UBM to confirm the diagnosis of PEX and identify patients at risk for operative complications.

Entities:  

Mesh:

Year:  2006        PMID: 16698482     DOI: 10.1016/j.jcrs.2006.01.015

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Ultrasound biomicroscopy in patients with unilateral pseudoexfoliation.

Authors:  Erkan Ünsal; Kadir Eltutar; Ilkay Muftuoglu; Tulay Alpar Akcetin; Yıldız Acar
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

2.  Immunohistochemical analysis of microsomal glutathione S-transferase 1 and clusterin expression in lens epithelial cells of patients with pseudoexfoliation syndrome.

Authors:  Joanna Stafiej; Marta Hałas-Wiśniewska; Magdalena Izdebska; Maciej Gagat; Dariusz Grzanka; Alina Grzanka; Grażyna Malukiewicz
Journal:  Exp Ther Med       Date:  2017-01-24       Impact factor: 2.447

3.  Scheimpflug Camera Measurement of Optical Density of the Corneal Epithelium, Stroma, and Endothelium in Patients with Pseudoexfoliation Syndrome.

Authors:  Dorota Urbaniak; Małgorzata Seredyka-Burduk; Waldemar Błoch; Grażyna Malukiewicz; Bartłomiej J Kałużny
Journal:  Med Sci Monit       Date:  2018-08-21

Review 4.  A Case-Cohort Study of Exfoliation Risk Factors and Literature Review.

Authors:  Ahmad M Mansour; Anastasios G P Konstas; Hana A Mansour; Abdul R Charbaji; Khalil M El Jawhari
Journal:  Middle East Afr J Ophthalmol       Date:  2021-04-30

Review 5.  Ultrasound biomicroscopy in glaucoma assessment.

Authors:  Vasile Potop; Valeria Coviltir; Speranţa Schmitzer; Christiana Diana Maria Dragosloveanu; Cătălina Ioana Ionescu; Miruna Gabriela Burcel; Maria Cristina Corbu; Dana Margareta Cornelia Dăscălescu
Journal:  Rom J Ophthalmol       Date:  2021 Apr-Jun

Review 6.  Anterior segment imaging in glaucoma: An updated review.

Authors:  Jessica S Maslin; Yaniv Barkana; Syril K Dorairaj
Journal:  Indian J Ophthalmol       Date:  2015-08       Impact factor: 1.848

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.