Literature DB >> 16698278

Ion trap collision-induced dissociation of human hemoglobin alpha-chain cations.

Tegafaw T Mekecha1, Ravi Amunugama, Scott A McLuckey.   

Abstract

Multiply protonated human hemoglobin alpha-chain species, ranging from [M + 4H]4+ to [M + 20H]20+, have been subjected to ion trap collisional activation. Cleavages at 88 of the 140 peptide bonds were indicated, summed over all charge states, although most product ion signals were concentrated in a significantly smaller number of channels. Consistent with previous whole protein ion dissociation studies conducted under similar conditions, the structural information inherent to a given precursor ion was highly sensitive to charge state. A strongly dominant cleavage at D75/M76, also noted previously in beam-type collisional activation studies, was observed for the [M + 8H]8+ to [M + 11H]11+ precursor ions. At lower charge states, C-terminal aspartic acid cleavages were also prominent but the most abundant products did not arise from the D75/M76 channel. The [M + 12H]12+-[M + 16H]16+ precursor ions generally yielded the greatest variety of amide bond cleavages. With the exception of the [M + 4H]4+ ion, all charge states showed cleavage at the L113/P114 bond. This cleavage proved to be the most prominent dissociation for charge states [M + 14H]14+ and higher. The diversity of dissociation channels observed within the charge state range studied potentially provides the opportunity to localize residues associated with variants via a top-down tandem mass spectrometry approach.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16698278     DOI: 10.1016/j.jasms.2006.01.004

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  43 in total

1.  Mass analysis at the advent of the 21st century.

Authors:  S A McLuckey; J M Wells
Journal:  Chem Rev       Date:  2001-02       Impact factor: 60.622

2.  Ion parking during ion/ion reactions in electrodynamic ion traps.

Authors:  Scott A McLuckey; Gavin E Reid; J Mitchell Wells
Journal:  Anal Chem       Date:  2002-01-15       Impact factor: 6.986

3.  Electrospray mass spectrometry: an efficient method to detect silent hemoglobin variants causing erythrocytosis.

Authors:  D K Rai; W J Griffiths; G Alvelius; B Landin
Journal:  Clin Chem       Date:  2001       Impact factor: 8.327

4.  A combined linear ion trap time-of-flight system with improved performance and MS(n) capabilities.

Authors:  B A Collings; J M Campbell; D Mao; D J Douglas
Journal:  Rapid Commun Mass Spectrom       Date:  2001       Impact factor: 2.419

Review 5.  Top-down proteomics.

Authors:  Neil L Kelleher
Journal:  Anal Chem       Date:  2004-06-01       Impact factor: 6.986

6.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

7.  Combined mass spectrometric methods for the characterization of human hemoglobin variants localized within alpha T9 peptide: identification of Hb Villeurbanne alpha 89 (FG1) His-->Tyr.

Authors:  C Déon; J C Promé; D Promé; A Francina; P Groff; G Kalmes; F Galactéros; H Wajcman
Journal:  J Mass Spectrom       Date:  1997-08       Impact factor: 1.982

8.  Rapid analysis of hemoglobin from whole human blood by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Authors:  C T Houston; J P Reilly
Journal:  Rapid Commun Mass Spectrom       Date:  1997       Impact factor: 2.419

9.  Cleavage N-terminal to proline: analysis of a database of peptide tandem mass spectra.

Authors:  Linda A Breci; David L Tabb; John R Yates; Vicki H Wysocki
Journal:  Anal Chem       Date:  2003-05-01       Impact factor: 6.986

Review 10.  Molecular diagnosis of haemoglobin disorders.

Authors:  B E Clark; S L Thein
Journal:  Clin Lab Haematol       Date:  2004-06
View more
  9 in total

1.  Relative information content and top-down proteomics by mass spectrometry: utility of ion/ion proton-transfer reactions in electrospray-based approaches.

Authors:  Jian Liu; Paul A Chrisman; David E Erickson; Scott A McLuckey
Journal:  Anal Chem       Date:  2007-02-01       Impact factor: 6.986

2.  Analysis of protein mixtures by electrospray mass spectrometry: effects of conformation and desolvation behavior on the signal intensities of hemoglobin subunits.

Authors:  Mark C Kuprowski; Brian L Boys; Lars Konermann
Journal:  J Am Soc Mass Spectrom       Date:  2007-04-15       Impact factor: 3.109

3.  Fragmentation of multiply-charged intact protein ions using MALDI TOF-TOF mass spectrometry.

Authors:  Zhaoyang Liu; Kevin L Schey
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-20       Impact factor: 3.109

4.  Top-Down Analysis of Small Plasma Proteins Using an LTQ-Orbitrap. Potential for Mass Spectrometry-Based Clinical Assays for Transthyretin and Hemoglobin.

Authors:  Roger Théberge; Giuseppe Infusini; Weiwei Tong; Mark E McComb; Catherine E Costello
Journal:  Int J Mass Spectrom       Date:  2011-03-01       Impact factor: 1.986

Review 5.  Protein identification strategies in MALDI imaging mass spectrometry: a brief review.

Authors:  Daniel J Ryan; Jeffrey M Spraggins; Richard M Caprioli
Journal:  Curr Opin Chem Biol       Date:  2018-11-23       Impact factor: 8.822

6.  Elucidating the site of protein-ATP binding by top-down mass spectrometry.

Authors:  Sheng Yin; Joseph A Loo
Journal:  J Am Soc Mass Spectrom       Date:  2010-01-18       Impact factor: 3.109

7.  Wooden-Tip Electrospray Mass Spectrometry Characterization of Human Hemoglobin in Whole Blood Sample for Thalassemia Screening: A Pilot Study.

Authors:  Tingting Huang; Ting Huang; Yongyi Zou; Kang Xie; Yinqin Shen; Wen Zhang; Shuhui Huang; Yanqiu Liu; Bicheng Yang
Journal:  Molecules       Date:  2022-06-20       Impact factor: 4.927

8.  Top-down protein identification of proteasome proteins with nanoLC-FT-ICR-MS employing data-independent fragmentation methods.

Authors:  Rajeswari Lakshmanan; Jeremy J Wolff; Rudy Alvarado; Joseph A Loo
Journal:  Proteomics       Date:  2014-03-26       Impact factor: 3.984

9.  Lymph is not a plasma ultrafiltrate: a proteomic analysis of injured patients.

Authors:  Monika Dzieciatkowska; Angelo D'Alessandro; Ernest E Moore; Max Wohlauer; Anirban Banerjee; Christopher C Silliman; Kirk C Hansen
Journal:  Shock       Date:  2014-12       Impact factor: 3.454

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.