Anders Helander1, Jonas P Bergström. 1. Department of Clinical Neuroscience, Karolinska Institutet and Karolinska University Hospital, Stockholm, Sweden. anders.helander@ki.se <anders.helander@ki.se>
Abstract
BACKGROUND: Carbohydrate-deficient transferrin (CDT) in serum is a biomarker used to identify individuals with sustained, heavy alcohol consumption. This study evaluated the performance of a new commercial method for CDT, the Bio-Rad %CDT by HPLC test, that measures relative amounts of separate transferrin glycoforms in proportion to total transferrin. METHOD: The samples used were two human serum pools (low/high disialotransferrin), 150 clinical sera with low to highly elevated disialotransferrin values, and 18 genetic transferrin variants. Glycoforms are separated on a gradient HPLC system, followed by specific measurement of the iron-transferrin complex at 460 nm. Comparison was made with an HPLC candidate reference method on an Agilent 1100 LC system. RESULTS: The Bio-Rad %CDT by HPLC test allowed for reproducible separation and quantification of the transferrin glycoforms within approximately 6 min. Genetic variants were readily identified. For the low and high serum pool, the total CV was 8.5% and 4.3%, respectively. The relative amounts of disialotransferrin, the main CDT glycoform, were in good agreement with the results of the HPLC candidate reference method (r(2)=0.998, p<0.0001). CONCLUSIONS: The present results demonstrated that the Bio-Rad %CDT by HPLC test is appropriate for confirmatory and routine %CDT testing in human serum, with the added advantage over previously published HPLC methods of an improved serum sample pretreatment and a shorter total analysis time.
BACKGROUND:Carbohydrate-deficient transferrin (CDT) in serum is a biomarker used to identify individuals with sustained, heavy alcohol consumption. This study evaluated the performance of a new commercial method for CDT, the Bio-Rad %CDT by HPLC test, that measures relative amounts of separate transferrin glycoforms in proportion to total transferrin. METHOD: The samples used were two human serum pools (low/high disialotransferrin), 150 clinical sera with low to highly elevated disialotransferrin values, and 18 genetic transferrin variants. Glycoforms are separated on a gradient HPLC system, followed by specific measurement of the iron-transferrin complex at 460 nm. Comparison was made with an HPLC candidate reference method on an Agilent 1100 LC system. RESULTS: The Bio-Rad %CDT by HPLC test allowed for reproducible separation and quantification of the transferrin glycoforms within approximately 6 min. Genetic variants were readily identified. For the low and high serum pool, the total CV was 8.5% and 4.3%, respectively. The relative amounts of disialotransferrin, the main CDT glycoform, were in good agreement with the results of the HPLC candidate reference method (r(2)=0.998, p<0.0001). CONCLUSIONS: The present results demonstrated that the Bio-Rad %CDT by HPLC test is appropriate for confirmatory and routine %CDT testing in human serum, with the added advantage over previously published HPLC methods of an improved serum sample pretreatment and a shorter total analysis time.
Authors: Susannah Tomkins; Elizabeth Allen; Olga Savenko; Jim McCambridge; Lyudmila Saburova; Nikolay Kiryanov; Alexey Oralov; Artyom Gil; David A Leon; Martin McKee; Diana Elbourne Journal: BMC Health Serv Res Date: 2008-03-31 Impact factor: 2.655
Authors: Matteo Vidali; Vincenza Bianchi; Marco Bagnati; Nadia Atzeni; Andrea Marco Bianchi; Giorgio Bellomo Journal: Biochem Med (Zagreb) Date: 2014-02-15 Impact factor: 2.313