Literature DB >> 16696687

Detection of fish nocardiosis by loop-mediated isothermal amplification.

T Itano1, H Kawakami, T Kono, M Sakai.   

Abstract

AIMS: Loop-mediated isothermal amplification (LAMP) is a novel method that amplifies DNA with high specificity and rapidity under isothermal conditions. In this study, using the LAMP method, a protocol for detecting Nocardia seriolae which is a causative agent of fish nocardiosis, was designed. METHODS AND
RESULTS: A set of four primers, two inner and two outer, were designed based on the sequence of the 16S-23S ribosomal RNA internal transcribed spacer region of N. seriolae. Time and temperature conditions for detection of N. seriolae were optimized for 60 min at 65 degrees C. Other fish pathogen was not amplified by this LAMP system. The detection of N. seriola using LAMP was found to be more sensitive than that by polymerase chain reaction.
CONCLUSIONS: LAMP is a highly sensitive and rapid diagnostic procedure for detection of N. seriolae. SIGNIFICANCE AND IMPACT OF THE STUDY: LAMP is a useful diagnostic method for fish nocardiosis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16696687     DOI: 10.1111/j.1365-2672.2006.02872.x

Source DB:  PubMed          Journal:  J Appl Microbiol        ISSN: 1364-5072            Impact factor:   3.772


  5 in total

1.  LAMP Method as One of the Best Candidates for Replacing with PCR Method.

Authors:  Masoud Keikha
Journal:  Malays J Med Sci       Date:  2018-02-28

2.  Identification, Molecular Cloning of IL-1β and Its Expression Profile during Nocardia seriolae Infection in Largemouth Bass, Micropterus salmoides.

Authors:  Ping-Yueh Ho; Omkar Byadgi; Pei-Chyi Wang; Ming-An Tsai; Li-Ling Liaw; Shih-Chu Chen
Journal:  Int J Mol Sci       Date:  2016-10-01       Impact factor: 5.923

Review 3.  Loop-mediated isothermal amplification: an emerging technology for detection of fish and shellfish pathogens.

Authors:  R Savan; T Kono; T Itami; M Sakai
Journal:  J Fish Dis       Date:  2005-10       Impact factor: 2.767

4.  Loop-mediated isothermal amplification as an emerging technology for detection of Yersinia ruckeri the causative agent of enteric red mouth disease in fish.

Authors:  Mona Saleh; Hatem Soliman; Mansour El-Matbouli
Journal:  BMC Vet Res       Date:  2008-08-12       Impact factor: 2.741

5.  Rapid detection of Salmonella Typhi by loop-mediated isothermal amplification (LAMP) method.

Authors:  J Abdullah; N Saffie; F A R Sjasri; A Husin; Z Abdul-Rahman; A Ismail; I Aziah; M Mohamed
Journal:  Braz J Microbiol       Date:  2015-03-04       Impact factor: 2.476

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.