Investigation of gamma knife image registration errors resulting from misalignment between the patient and the imaging axis.

George Cernica1, Zhou Wang, Harish Malhotra, Steven de Boer, Matthew B Podgorsak.   

Abstract

The ability of Leksell GammaPlan to perform stereotactic space localizations with image sets where there is misalignment of the patient's head (stereotactic frame and fiducial apparatus) relative to the computed tomography (CT) scanner coordinate system was studied. Misalignment is sometimes necessary for patient comfort. Results equally apply to magnetic resonance imaging. Seven 0.5 mm diameter CT-visible spheres were rigidly mounted to a string tied tightly at each end to diagonally opposite posts attached to a Leksell stereotactic frame. A standard CT fiducial box was applied to the frame in the usual clinical manner. A baseline CT scan (1 mm slice thickness) was obtained with the fiducial box perfectly aligned with the scanner axis. After localization of the image set, the (x,y,z) coordinate of the center of each sphere was recorded. Repeat CT scans with varying fiducial box misalignments with the imaging axis were subsequently obtained. The mean difference between the base line and the respective coordinates in misaligned geometries was approximately 0.2 mm (sigma=0.2 mm), well within the accuracy of the image sets and the delivery of radiosurgery with the Gamma Knife.

Entities:  

Mesh:

Year:  2006        PMID: 16696470     DOI: 10.1118/1.2179751

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Validation of accuracy in image co-registration with computed tomography and magnetic resonance imaging in Gamma Knife radiosurgery.

Authors:  Hisato Nakazawa; Yoshimasa Mori; Masataka Komori; Yuta Shibamoto; Takahiko Tsugawa; Tatsuya Kobayashi; Chisa Hashizume
Journal:  J Radiat Res       Date:  2014-04-29       Impact factor: 2.724

2.  Assessment of image co-registration accuracy for frameless gamma knife surgery.

Authors:  Hyun-Tai Chung; Jeong Hun Kim; Jin Wook Kim; Sun Ha Paek; Dong Gyu Kim; Kook Jin Chun; Tae Hoon Kim; Yong Kyun Kim
Journal:  PLoS One       Date:  2018-03-02       Impact factor: 3.240

3.  Evaluation of stability of stereotactic space defined by cone-beam CT for the Leksell Gamma Knife Icon.

Authors:  Ismail AlDahlawi; Dheerendra Prasad; Matthew B Podgorsak
Journal:  J Appl Clin Med Phys       Date:  2017-04-17       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.