Literature DB >> 16696372

Concepts of registration and correction of head motion in positron emission tomography.

Lutz Tellmann1, Roger Fulton, Uwe Pietrzyk, Ingo Nickel, Isabelle Stangier, Oliver Winz, Hans Herzog.   

Abstract

The long acquisition times (up to hours) in PET brain imaging bear a high risk of head motion, which results in artefacts like blurred images and may even lead to misinterpretation and useless data. With the increased resolution of high performance PET scanners, the influence of head movements becomes more and more relevant. Especially in the analysis of small brain structures, e.g. during ROI-analysis, head motion results in inaccuracies of quantified data. This may also influence the kinetic analysis and generate artifacts in parametric images calculated from a motion-affected image sequence. This work presents the feasibility of head motion registration using an external motion tracking system. The implementation of the multi acquisition frame method and an event-by-event method to correct PET data for motion are described. The effects of motion correction are demonstrated on the basis of phantom measurements and patient data. The influence of motion correction on parametric imaging is described in a receptor study.

Entities:  

Mesh:

Year:  2006        PMID: 16696372     DOI: 10.1078/0939-3889-00293

Source DB:  PubMed          Journal:  Z Med Phys        ISSN: 0939-3889            Impact factor:   4.820


  5 in total

1.  MR-based motion correction for PET imaging using wired active MR microcoils in simultaneous PET-MR: phantom study.

Authors:  Chuan Huang; Jerome L Ackerman; Yoann Petibon; Thomas J Brady; Georges El Fakhri; Jinsong Ouyang
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

2.  Motion compensation for brain PET imaging using wireless MR active markers in simultaneous PET-MR: phantom and non-human primate studies.

Authors:  Chuan Huang; Jerome L Ackerman; Yoann Petibon; Marc D Normandin; Thomas J Brady; Georges El Fakhri; Jinsong Ouyang
Journal:  Neuroimage       Date:  2014-01-10       Impact factor: 6.556

3.  Image reconstruction for PET/CT scanners: past achievements and future challenges.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  Imaging Med       Date:  2010-10-01

4.  Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI.

Authors:  Jakob M Slipsager; Andreas H Ellegaard; Stefan L Glimberg; Rasmus R Paulsen; M Dylan Tisdall; Paul Wighton; André van der Kouwe; Lisbeth Marner; Otto M Henriksen; Ian Law; Oline V Olesen
Journal:  PLoS One       Date:  2019-04-19       Impact factor: 3.240

5.  MR-based PET motion correction procedure for simultaneous MR-PET neuroimaging of human brain.

Authors:  Marcus Görge Ullisch; Jürgen Johann Scheins; Christoph Weirich; Elena Rota Kops; Abdullah Celik; Lutz Tellmann; Tony Stöcker; Hans Herzog; Nadim Jon Shah
Journal:  PLoS One       Date:  2012-11-12       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.