Literature DB >> 16691161

[Sonography of the eye and orbit with a multipurpose ultrasound unit].

O Bergès1, P Koskas, F Lafitte, J-D Piekarski.   

Abstract

Our goal is to help echographists and radiologists become familiar with the various possibilities indications, technique and results of ophtalmic ultrasonography. We used a multipurpose ultrasound unit. The frequency of the transducer has to be equal or superior to 7.5 MHz. Color Doppler allowing the study of low flows is useful. The study must be standardized: the first step is to obtain measurements of both eyes. Then the entire globe is systematically evaluated. Finally, the orbital structures and vessels of the eye and orbit are analized. After a review of the anatomy and the normal sonographic features, the main indications are described as well as the main pathologies. Special attention is paid to intravitreal hemorrhage, retinal and choroidal detachments, intraocular tumors and orbital space occupying lesions.

Entities:  

Mesh:

Year:  2006        PMID: 16691161     DOI: 10.1016/s0221-0363(06)74012-4

Source DB:  PubMed          Journal:  J Radiol        ISSN: 0221-0363


  8 in total

1.  High-resolution, three-dimensional, and contrast-enhanced ultrasonographic findings in diseases of the eye().

Authors:  L M Sconfienza; F Lacelli; A Ardemagni; N Perrone; M Bertolotto; R Padolecchia; G Serafini
Journal:  J Ultrasound       Date:  2010-11-12

2.  Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients.

Authors:  Thomas Geeraerts; Sybille Merceron; Dan Benhamou; Bernard Vigué; Jacques Duranteau
Journal:  Intensive Care Med       Date:  2008-05-29       Impact factor: 17.440

3.  The Authors Reply: Correlation Between Ultrasonographic Optic Nerve Sheath Diameter and Intracranial Pressure in Patients with Aneurysmal Subarachnoid Hemorrhage.

Authors:  Alessio Caccioppola; Tommaso Zoerle; Nino Stocchetti
Journal:  Neurocrit Care       Date:  2020-09-21       Impact factor: 3.210

4.  Can sonographic measurement of optic nerve sheath diameter be used to detect raised intracranial pressure in patients with tuberculous meningitis? A prospective observational study.

Authors:  Shruti V Sangani; Samira Parikh
Journal:  Indian J Radiol Imaging       Date:  2015 Apr-Jun

Review 5.  Ocular ultrasonography focused on the posterior eye segment: what radiologists should know.

Authors:  Marcela De La Hoz Polo; Anna Torramilans Lluís; Oscar Pozuelo Segura; Albert Anguera Bosque; Catalina Esmerado Appiani; Josep Maria Caminal Mitjana
Journal:  Insights Imaging       Date:  2016-02-24

6.  Bedside Ultrasonographic Assessment of Optic Nerve Sheath Diameter As a Means of Detecting Raised Intracranial Pressure in Neuro-Trauma Patients: A Cross-Sectional Study.

Authors:  Amandeep Kaur; Parshotam L Gautam; Shruti Sharma; Vikram P Singh; Sarit Sharma
Journal:  Ann Indian Acad Neurol       Date:  2020-05-28       Impact factor: 1.383

7.  Ocular sonography in patients with raised intracranial pressure: the papilloedema revisited.

Authors:  Thomas Geeraerts; Jacques Duranteau; Dan Benhamou
Journal:  Crit Care       Date:  2008-05-16       Impact factor: 9.097

8.  [Value of ultrasonography in eye injuries at Parakou (Benin)].

Authors:  Kofi-Mensa Savi de Tove; Abel Rodrigue Assavedo; Patricia Yekpe; Zakari Nikiema; Olivier Biaou; Vicentia Boco
Journal:  Pan Afr Med J       Date:  2013-07-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.