Literature DB >> 16690491

Quantification of serum 25-hydroxyvitamin D(2) and D(3) using HPLC-tandem mass spectrometry and examination of reference intervals for diagnosis of vitamin D deficiency.

Amy K Saenger1, Thomas J Laha, Deborah E Bremner, Sayed M H Sadrzadeh.   

Abstract

Serum levels of 25-hydroxyvitamin D are important in establishing true vitamin D levels in humans. The purposes of this study were to develop a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection of 25-hydroxyvitamin D(2) and D(3) and establish reference intervals for these analytes. Chromatographic separation of 25(OH)D(2) and 25(OH)D(3) was achieved after adding deuterated Delta(9)-tetrahydrocannabinol (D(9)-THC-D(3)) and organic extraction. The 3 ions were ionized using positive electrospray ionization and detected in the multiple-reaction monitoring mode using mass (m)/charge (z) transitions of 318.15 > 196.20 (Delta(9)-THC-D(3)), 401.15 > 365.2 (25(OH)D(3)), and 413.15 > 355.20 (25(OH)D(2)). Reference interval study results were compared with current 25(OH)D recommendations. Elution of 25(OH)D(2), 25(OH)D(3), and Delta(9)-THC-D(3) was achieved after 3.0 minutes (total run time, 6.0 minutes). Within- and between-run coefficients of variation were less than 11%. Deming regression of radioimmunoassay and LC-MS/MS methods for total 25(OH)D levels yielded a slope of 0.97 (95% confidence interval, 0.88-1.05) and y-intercept of -1.74 ng/mL. Reference intervals were less than recommended levels (D(2), 0.0-12.1; D(3), 5.5-41.4; total vitamin D, 6.0-43.5 ng/mL [0-30, 14-103, 15-109 nmol/L, respectively]) with no statistically significant differences in race, age, or sex. This LC-MS/MS method provides a rapid, accurate, sensitive, and cost-effective alternative to other methods for detection of 25(OH)D(2) and 25(OH)D(3) at nanomolar concentrations.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16690491     DOI: 10.1309/J32U-F7GT-QPWN-25AP

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  41 in total

1.  Blood 25-hydroxyvitamin D3 concentrations and incident sporadic colorectal adenoma risk: a pooled case-control study.

Authors:  Veronika Fedirko; Roberd M Bostick; Michael Goodman; W Dana Flanders; Myron D Gross
Journal:  Am J Epidemiol       Date:  2010-07-22       Impact factor: 4.897

2.  Tandem mass spectrometry improves the accuracy of free thyroxine measurements during pregnancy.

Authors:  Natasa Kahric-Janicic; Steven J Soldin; Offie P Soldin; Threvia West; Jianghong Gu; Jacqueline Jonklaas
Journal:  Thyroid       Date:  2007-04       Impact factor: 6.568

3.  Principles and applications of liquid chromatography-mass spectrometry in clinical biochemistry.

Authors:  James J Pitt
Journal:  Clin Biochem Rev       Date:  2009-02

4.  Heritability and environmental factors affecting vitamin D status in rural Chinese adolescent twins.

Authors:  Lester M Arguelles; Craig B Langman; Adolfo J Ariza; Farah N Ali; Kimberley Dilley; Heather Price; Xin Liu; Shanchun Zhang; Xiumei Hong; Binyan Wang; Houxun Xing; Zhiping Li; Xue Liu; Wenbin Zhang; Xiping Xu; Xiaobin Wang
Journal:  J Clin Endocrinol Metab       Date:  2009-06-23       Impact factor: 5.958

5.  Cord blood vitamin D status impacts innate immune responses.

Authors:  Valencia P Walker; Xiaoran Zhang; Ida Rastegar; Philip T Liu; Bruce W Hollis; John S Adams; Robert L Modlin
Journal:  J Clin Endocrinol Metab       Date:  2011-04-06       Impact factor: 5.958

Review 6.  DIAGNOSIS OF ENDOCRINE DISEASE: How reliable are free thyroid and total T3 hormone assays?

Authors:  Kerry J Welsh; Steven J Soldin
Journal:  Eur J Endocrinol       Date:  2016-12       Impact factor: 6.664

7.  A rubber transfer gasket to improve the throughput of liquid-liquid extraction in 96-well plates: application to vitamin D testing.

Authors:  Andrew N Hoofnagle; Thomas J Laha; Thomas F Donaldson
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2010-04-24       Impact factor: 3.205

Review 8.  Vitamin D and metabolites measurement by tandem mass spectrometry.

Authors:  Johannes M W van den Ouweland; Michael Vogeser; Silvia Bächer
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

9.  Quantitative determination of vitamin D metabolites in plasma using UHPLC-MS/MS.

Authors:  Shujing Ding; Inez Schoenmakers; Kerry Jones; Albert Koulman; Ann Prentice; Dietrich A Volmer
Journal:  Anal Bioanal Chem       Date:  2010-07-14       Impact factor: 4.142

10.  A simple, rapid atmospheric pressure chemical ionization liquid chromatography tandem mass spectrometry method for the determination of 25-hydroxyvitamin D2 and D3.

Authors:  Uttam Garg; Ada Munar; Clinton Frazee; David Scott
Journal:  J Clin Lab Anal       Date:  2012-09       Impact factor: 2.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.