Dosimetric comparison of two different three-dimensional conformal external beam accelerated partial breast irradiation techniques.

Kevin R Kozak1, Karen P Doppke, Angela Katz, Alphonse G Taghian.   

Abstract

PURPOSE: We compare the dosimetry of two techniques for three-dimensional, conformal, external beam, accelerated partial breast irradiation (3D-CPBI) in the supine position. METHODS AND MATERIALS: Sixteen patients with Stage I breast cancer had PBI treatment plans generated using the multiple, noncoplanar photon field technique and the three-field, mixed-modality technique. Planning target volumes (PTVs; lumpectomy site plus 1.5-2.0 cm margin) and total dose (32 Gy) were held constant to facilitate dosimetric comparisons. Plans were optimized for conformality and PTV coverage.
RESULTS: Mixed-modality plans employed fewer fields than multiple, noncoplanar photon field plans (mean 3.2 vs. 4.1). Both techniques provided comparable PTV coverage and in all cases, 95% of the PTV received 90% of the prescribed dose. Volumes of ipsilateral breast receiving greater than 16 Gy were similar; however, the mean volume of ipsilateral breast receiving 8 Gy was significantly lower for mixed-modality plans (58% vs. 66%). No differences in the volumes of ipsilateral lung or heart receiving greater than 5 Gy were observed, however, the mixed-modality technique delivered 2.5 Gy to larger volumes of these organs.
CONCLUSIONS: Both techniques for supine position, 3D-CPBI provides excellent normal tissue sparing with adequate PTV coverage. The multiple, noncoplanar photon field technique exposes smaller volumes of ipsilateral lung and heart to low dose radiation at the expense of increased plan complexity and larger irradiated breast volumes.

Entities:  

Mesh:

Year:  2006        PMID: 16690427     DOI: 10.1016/j.ijrobp.2005.12.053

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

Review 1.  Accelerated Partial Breast Irradiation (APBI): A review of available techniques.

Authors:  Christopher F Njeh; Mark W Saunders; Christian M Langton
Journal:  Radiat Oncol       Date:  2010-10-04       Impact factor: 3.481

2.  Accelerated partial breast irradiation: what is dosimetric effect of advanced technology approaches?

Authors:  Jean M Moran; Merav A Ben-David; Robin B Marsh; James M Balter; Kent A Griffith; James A Hayman; Lori J Pierce
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-06-18       Impact factor: 7.038

3.  Comparison Of Accelerated Partial Breast Radiation Therapy And External Beam Radiation Therapy By Treatment Planning Indices.

Authors:  Peyman Hejazi; Maede Jafari Tirtash; Alireza Khoshbin Khoshnazar
Journal:  Breast Cancer (Dove Med Press)       Date:  2019-11-14

4.  Individually selected teletherapy technique for accelerated partial breast irradiation.

Authors:  Renáta L Kószó; Zsuzsanna Kahán; Barbara Darázs; Ferenc Rárosi; Zoltán Varga
Journal:  Rep Pract Oncol Radiother       Date:  2021-12-30

5.  Optimizing of the tangential technique and supraclavicular fields in 3 dimensional conformal radiation therapy for breast cancer.

Authors:  Keyvan Jabbari; Nazli Azarmahd; Shadi Babazade; Alireza Amouheidari
Journal:  J Med Signals Sens       Date:  2013-04

6.  Cardiac dose evaluation for 3-dimensional conformal partial breast irradiation compared with whole breast irradiation.

Authors:  Ashley A Gale; Anudh K Jain; Laura A Vallow; Christopher F Serago; Steven J Buskirk; Michael G Heckman
Journal:  J Appl Clin Med Phys       Date:  2009-01-14       Impact factor: 2.102