Literature DB >> 16690347

Clinical performance of daily disposable soft contact lenses using sustained release technology.

Rachael C Peterson1, James S Wolffsohn, Joachim Nick, Lynn Winterton, John Lally.   

Abstract

PURPOSE: Polyvinyl alcohol (PVA) is a successful tear film stabiliser and is widely used in comfort drops and some soft contact lens materials. A PVA-containing lens, nelfilcon A has been modified to include additional (non-functional) PVA in order to provide improved comfort. This study aims to examine the clinical performance of this nelfilcon A lens with AquaRelease (AquaRelease).
METHODS: Two contralateral, investigator masked, open label, subjective and objective evaluations were conducted. The first examined the effect of adding increased molecular weight PVA to nelfilcon A (n=5), and the second compared this AquaRelease lens to ocufilcon B (n=34). The principal measures were non-invasive break-up time (NIBUT) and subjective comfort, which were assessed at the beginning and end of a week of daily wear, and three times throughout 1 day at 8, 12 and 16 h.
RESULTS: All subjects successfully completed the daily wearing schedule of 16h. On initial insertion, subjective comfort and NIBUT improved for AquaRelease than original nelfilcon A lenses (p<0.05). Initial comfort was better for AquaRelease compared to ocufilcon B lenses (p=0.01); however, NIBUT was not statistically different (11.7+/-15.6s versus 8.4+/-6.8s; p=0.26). Subjective comfort decreased with time (p<0.001), but there was no significant difference between AquaRelease and ocufilcon B lenses (p=0.16). NIBUT was not significantly affected by time (p=0.56) or between lenses (p=0.33). At the end of a weeks' wear, subjective initial, end-of-day, overall comfort and vision were rated significantly better with AquaRelease than ocufilcon B (p<0.01).
CONCLUSIONS: Release of additional non-functionalised PVA from the nelfilcon A lenses appears to enhance comfortable contact lens wear.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16690347     DOI: 10.1016/j.clae.2006.03.004

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  7 in total

1.  The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on neurobiology.

Authors:  Fiona Stapleton; Carl Marfurt; Blanka Golebiowski; Mark Rosenblatt; David Bereiter; Carolyn Begley; Darlene Dartt; Juana Gallar; Carlos Belmonte; Pedram Hamrah; Mark Willcox
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-10-18       Impact factor: 4.799

2.  Objective Analysis of Pre-Lens Tear Film Stability of Daily Disposable Contact Lenses Using Ring Mire Projection.

Authors:  Sebastian Marx; Julia Eckstein; Wolfgang Sickenberger
Journal:  Clin Optom (Auckl)       Date:  2020-11-20

3.  Analysis of polyvinyl alcohol release from commercially available daily disposable contact lenses using an in vitro eye model.

Authors:  Chau-Minh Phan; Hendrik Walther; Donald Riederer; Charis Lau; Kathrine Osborn Lorenz; Lakshman Nagapatnam Subbaraman; Lyndon Jones
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-10-16       Impact factor: 3.368

4.  Novel daily disposable therapeutic contact lenses based on chitosan and regenerated silk fibroin for the ophthalmic delivery of diclofenac sodium.

Authors:  Rachasit Jeencham; Manote Sutheerawattananonda; Saowaluk Rungchang; Waree Tiyaboonchai
Journal:  Drug Deliv       Date:  2020-12       Impact factor: 6.419

5.  The Bio-Tribological Effect of Poly-Gamma-Glutamic Acid in the Lysozyme-Ionic Contact Lens System.

Authors:  Chen-Ying Su; Lung-Kun Yeh; Chi-Chun Lai; Mihaela Dubuisson; Yi-Fei Tsao; Ching-Li Tseng; And Hsu-Wei Fang
Journal:  Polymers (Basel)       Date:  2020-01-07       Impact factor: 4.329

6.  A Potential Alternative Orodispersible Formulation to Prednisolone Sodium Phosphate Orally Disintegrating Tablets.

Authors:  Essam A Tawfik; Mariagiovanna Scarpa; Hend E Abdelhakim; Haitham A Bukhary; Duncan Q M Craig; Susan A Barker; Mine Orlu
Journal:  Pharmaceutics       Date:  2021-01-19       Impact factor: 6.321

7.  Subjective Comparison of Pre-Lens Tear Film Stability of Daily Disposable Contact Lenses Using Ring Mire Projection.

Authors:  Christiane Müller; Sebastian Marx; Julia Wittekind; Wolfgang Sickenberger
Journal:  Clin Optom (Auckl)       Date:  2020-02-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.