Literature DB >> 16689029

Accuracy of intraoral data acquisition in comparison to the conventional impression.

R G Luthardt1, R Loos, S Quaas.   

Abstract

The achievable accuracy is a decisive parameter for the comparison of direct intraoral digitization with the conventional impression. The objective of the study was therefore to compare the accuracy of the reproduction of a model situation by intraoral digitization vs. the conventional procedure consisting of impression taking, model production, and extraoral digitization. Proceeding from a die model with a prepared tooth 16, the reference data set of the teeth 15, 16 and 17 was produced with an established procedure by means ofextraoral digitization. For the simulated intraoral data acquisition of the master model (Cerec 3D camera, Sirona, Bensheim), the camera was fastened on a stand for the measurement and the teeth digitized seven times each in defined views (occlusal, and in each case inclined by 20 degrees, from the mesio-proximal, disto-proximal, vestibular and oral aspect). Matching was automated (comparative data sets B1-B5). A clinically perfect one-step putty-and-wash impression was taken from the starting model. The model produced under defined conditions was digitized extraorally five times (digi-SCAN, comparative data sets C1-C5). The data sets B1-B5 and C1-C5 were assigned to the reference data set by means of best-fit matching and the root of the mean quadratic deviation (RMS; root mean square) calculated. The deviations were visualized, and mean positive, negative and absolute deviations calculated. The mean RMS was 27.9 microm (B1-B5) or 18.8 microm (C1-C5). The mean deviations for the prepared tooth were 18 microm/-17 microm (B1-B5) and 9 microm /-9 microm (C1-C5). For tooth 15, the mean deviations were 22 microm/-19 microm (B1-B5) and 15 microm/-16 microm (C1-C5). The intraoral method showed good results with deviations from the CAD starting model of approx. 17 microm, related to the prepared tooth 16. On the whole, in this in-vitro study, extraoral digitization with impression taking and model production showed higher accuracy than intraoral digitization. Since the inaccuracies in the conventional impression under real clinical conditions may be higher than the values determined above, a comparison under clinical conditions should be performed subsequently.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16689029

Source DB:  PubMed          Journal:  Int J Comput Dent        ISSN: 1463-4201            Impact factor:   1.883


  27 in total

1.  In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.

Authors:  Andreas Ender; Moritz Zimmermann; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-11-07       Impact factor: 3.573

2.  Accuracy of full-arch scans using intraoral scanners.

Authors:  Sebastian B M Patzelt; Archontia Emmanouilidi; Susanne Stampf; Joerg R Strub; Wael Att
Journal:  Clin Oral Investig       Date:  2013-11-17       Impact factor: 3.573

3.  Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Daniel Edelhoff; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-06-04       Impact factor: 3.573

4.  Precision of guided scanning procedures for full-arch digital impressions in vivo.

Authors:  Moritz Zimmermann; Christina Koller; Moritz Rumetsch; Andreas Ender; Albert Mehl
Journal:  J Orofac Orthop       Date:  2017-07-21       Impact factor: 1.938

5.  In vitro evaluation of prosthodontic impression on natural dentition: a comparison between traditional and digital techniques.

Authors:  G Malaguti; R Rossi; B Marziali; A Esposito; G Bruno; C Dariol; A DI Fiore
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

6.  Accuracy of digital and conventional impression techniques and workflow.

Authors:  Paul Seelbach; Cora Brueckel; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2012-10-21       Impact factor: 3.573

7.  Accuracy of digital models obtained by direct and indirect data capturing.

Authors:  Jan-Frederik Güth; Christine Keul; Michael Stimmelmayr; Florian Beuer; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2012-07-31       Impact factor: 3.573

8.  Accuracy of five intraoral scanners compared to indirect digitalization.

Authors:  Jan-Frederik Güth; Cornelius Runkel; Florian Beuer; Michael Stimmelmayr; Daniel Edelhoff; Christine Keul
Journal:  Clin Oral Investig       Date:  2016-07-12       Impact factor: 3.573

9.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

10.  [Effect of disinfectant with benzethon chloramine and isopropanol as main active ingredients on the accuracy of dental impression].

Authors:  D Xu; D H Wei; Y C Zhang; P DI; Y Lin
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.