Literature DB >> 16688260

Ex vivo characterization of sub-10-fs pulses.

Adam M Larson1, Alvin T Yeh.   

Abstract

An all-mirror dispersion-compensation setup is used to correct for quadratic and cubic phase distortions induced within a custom nonlinear optical microscope. Mouse tail tendon is used to characterize sub-10-fs pulses by interferometric autocorrelation. This is an ideal method for characterizing dispersion from the optical system, immersion medium, and wet biological sample. The generation of very short autocorrelations demonstrates the ability to compensate for phase distortions within the imaging system and efficient second-harmonic upconversion of the ultrashort pulse spectrum within collagen. Compensated autocorrelation traces are presented for biologically relevant objective lenses.

Entities:  

Mesh:

Year:  2006        PMID: 16688260     DOI: 10.1364/ol.31.001681

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  12 in total

1.  Enabling tools for engineering collagenous tissues integrating bioreactors, intravital imaging, and biomechanical modeling.

Authors:  Laura E Niklason; Alvin T Yeh; Elizabeth A Calle; Yuqiang Bai; Arturo Valentín; Jay D Humphrey
Journal:  Proc Natl Acad Sci U S A       Date:  2009-12-01       Impact factor: 11.205

2.  Mechanical assessment of elastin integrity in fibrillin-1-deficient carotid arteries: implications for Marfan syndrome.

Authors:  Jacopo Ferruzzi; Melissa J Collins; Alvin T Yeh; Jay D Humphrey
Journal:  Cardiovasc Res       Date:  2011-07-05       Impact factor: 10.787

3.  Passive pressure-diameter relationship and structural composition of rat mesenteric lymphangions.

Authors:  Elaheh Rahbar; Jon Weimer; Holly Gibbs; Alvin T Yeh; Christopher D Bertram; Michael J Davis; Michael A Hill; David C Zawieja; James E Moore
Journal:  Lymphat Res Biol       Date:  2012-11-12       Impact factor: 2.589

4.  Perivascular tethering modulates the geometry and biomechanics of cerebral arterioles.

Authors:  Samantha M Steelman; Qiaofeng Wu; Hallie P Wagner; Alvin T Yeh; Jay D Humphrey
Journal:  J Biomech       Date:  2010-07-22       Impact factor: 2.712

5.  ULTRASHORT PULSE MULTISPECTRAL NONLINEAR OPTICAL MICROSCOPY.

Authors:  Adam M Larson; Anthony Lee; Po-Feng Lee; Kayla J Bayless; Alvin T Yeh
Journal:  J Innov Opt Health Sci       Date:  2009-01-01

6.  Characterization of engineered tissue development under biaxial stretch using nonlinear optical microscopy.

Authors:  Jin-Jia Hu; Jay D Humphrey; Alvin T Yeh
Journal:  Tissue Eng Part A       Date:  2009-07       Impact factor: 3.845

7.  Advances in multiphoton microscopy technology.

Authors:  Erich E Hoover; Jeff A Squier
Journal:  Nat Photonics       Date:  2013-02-01       Impact factor: 38.771

8.  Cornea microstructure and mechanical responses measured with nonlinear optical and optical coherence microscopy using sub-10-fs pulses.

Authors:  Qiaofeng Wu; Brian E Applegate; Alvin T Yeh
Journal:  Biomed Opt Express       Date:  2011-04-11       Impact factor: 3.732

9.  Loss of smooth muscle α-actin effects on mechanosensing and cell-matrix adhesions.

Authors:  M P Massett; B C Bywaters; H C Gibbs; J P Trzeciakowski; S Padgham; J Chen; G Rivera; A T Yeh; D M Milewicz; A Trache
Journal:  Exp Biol Med (Maywood)       Date:  2020-02-17

10.  Nck deficiency is associated with delayed breast carcinoma progression and reduced metastasis.

Authors:  David C Morris; Julia L Popp; Leung K Tang; Holly C Gibbs; Emily Schmitt; Sankar P Chaki; Briana C Bywaters; Alvin T Yeh; Weston W Porter; Robert C Burghardt; Rola Barhoumi; Gonzalo M Rivera
Journal:  Mol Biol Cell       Date:  2017-09-27       Impact factor: 4.138

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.