Literature DB >> 16685734

Blipped multi gradient-echo slice excitation profile imaging (bmGESEPI) for fast T2 * measurements with macroscopic B0 inhomogeneity compensation.

Trong-Kha Truong1, Donald W Chakeres, Douglas W Scharre, David Q Beversdorf, Petra Schmalbrock.   

Abstract

With the rapid development of human MRI at field strengths > or = 7 T, knowledge of T(2) (*) relaxation times at such field strengths is needed to optimize acquisition parameters and understand relaxation mechanisms in many applications. However, standard T(2) (*) measurements (e.g., using conventional multiecho gradient-echo (GE) sequences) are affected by macroscopic static magnetic field (B(0)) inhomogeneities, which are particularly severe at high field strength. The multi-GE slice excitation profile imaging (mGESEPI) method was developed for T(2) (*) measurements in the presence of macroscopic B(0) inhomogeneity, but it requires excessive acquisition times at field strengths > or = 7 T. In this paper a more efficient technique, named blipped mGESEPI (bmGESEPI), is proposed. To demonstrate its advantages, T(2) (*) maps were acquired using a conventional multiecho GE method, the mGESEPI method, and the bmGESEPI method in postmortem and in vivo human brains at 8 T. Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16685734     DOI: 10.1002/mrm.20916

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  R*(2) mapping in the presence of macroscopic B₀ field variations.

Authors:  Diego Hernando; Karl K Vigen; Ann Shimakawa; Scott B Reeder
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

Review 2.  Clinical magnetic resonance imaging of brain tumors at ultrahigh field: a state-of-the-art review.

Authors:  William T C Yuh; Greg A Christoforidis; Regina Maria Koch; Steffen Sammet; Petra Schmalbrock; Ming Yang; Michael V Knopp
Journal:  Top Magn Reson Imaging       Date:  2006-04

3.  Voxel spread function method for correction of magnetic field inhomogeneity effects in quantitative gradient-echo-based MRI.

Authors:  Dmitriy A Yablonskiy; Alexander L Sukstanskii; Jie Luo; Xiaoqi Wang
Journal:  Magn Reson Med       Date:  2012-12-11       Impact factor: 4.668

4.  Improved susceptibility weighted imaging method using multi-echo acquisition.

Authors:  Sung Suk Oh; Se-Hong Oh; Yoonho Nam; Dongyeob Han; Randall B Stafford; Jinyoung Hwang; Dong-Hyun Kim; HyunWook Park; Jongho Lee
Journal:  Magn Reson Med       Date:  2013-09-16       Impact factor: 4.668

Review 5.  Visualizing the Human Subcortex Using Ultra-high Field Magnetic Resonance Imaging.

Authors:  M C Keuken; B R Isaacs; R Trampel; W van der Zwaag; B U Forstmann
Journal:  Brain Topogr       Date:  2018-03-02       Impact factor: 3.020

6.  Adaptive slice-specific z-shimming for 2D spoiled gradient-echo sequences.

Authors:  Martin Soellradl; Johannes Strasser; Andreas Lesch; Rudolf Stollberger; Stefan Ropele; Christian Langkammer
Journal:  Magn Reson Med       Date:  2020-09-10       Impact factor: 4.668

7.  Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences.

Authors:  Martin Soellradl; Andreas Lesch; Johannes Strasser; Lukas Pirpamer; Rudolf Stollberger; Stefan Ropele; Christian Langkammer
Journal:  Magn Reson Med       Date:  2019-12-23       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.