Literature DB >> 16683084

Volumetric evaluation of therapy response in patients with lung metastases. Preliminary results with a computer system (CAD) and comparison with unidimensional measurements.

F Fraioli1, L Bertoletti, A Napoli, F A Calabrese, R Masciangelo, E Cortesi, C Catalano, R Passariello.   

Abstract

PURPOSE: The aim of this study was to assess the efficacy of a Computer-Aided Detection (CAD) system in the identification of lung metastases and to compare the volumetric CAD measurements with unidimensional observer measurements in the evaluation of treatment response in oncology patients.
MATERIALS AND METHODS: Two observers (A and B) evaluated nine patients undergoing lung computed tomography (CT) just before and immediately after treatment with chemotherapy. Multislice CT scans were performed before and after the injection of contrast material with a high-resolution protocol (collimation 4x1 mm, 100 mAs, 120 kV). Response Evaluation Criteria in Solid Tumours (RECIST) criteria were used to consider the disease as stable, increased or decreased. Subsequently, target lesions (most significant lesions identified before and after chemotherapy) were evaluated with a computerised system (CAD) to establish volumetric measurements. Observers' unidimensional measurements and CAD volumetric measurements were analysed for comparison.
RESULTS: Twenty-four nodules (diameter: 5-18 mm in the first study and 4-20 mm in the follow-up study) were included. Observers agreed in the assessment of therapy response in 21 nodules: eight were considered to have increased in size, and 13 were judged stable. Observer and CAD measurements disagreed in three nodules: two were considered stable by radiologists and increased by CAD; one was considered increased by radiologists and stable by CAD.As regards patient response, radiologists disagreed in two cases. CAD and observers did not agree in one case.
CONCLUSIONS: Our preliminary data suggest that volumetric measurements can modify the diagnostic and therapeutic evaluation of oncology patients under chemotherapy.CAD volumetric measurements allow an easy and objective evaluation, reducing interobserver variability in the evaluation of chemotherapy response.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16683084     DOI: 10.1007/s11547-006-0035-2

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  7 in total

Review 1.  The pulmonary nodule: clinical and radiological characteristics affecting a diagnosis of malignancy.

Authors:  L Cardinale; F Ardissone; S Novello; M Busso; F Solitro; M Longo; D Sardo; M Giors; C Fava
Journal:  Radiol Med       Date:  2009-05-29       Impact factor: 3.469

Review 2.  CAD (computed-aided detection) and CADx (computer aided diagnosis) systems in identifying and characterising lung nodules on chest CT: overview of research, developments and new prospects.

Authors:  F Fraioli; G Serra; R Passariello
Journal:  Radiol Med       Date:  2010-01-15       Impact factor: 3.469

3.  A novel, reproducible, and objective method for volumetric magnetic resonance imaging assessment of enhancing glioblastoma.

Authors:  Charles W Kanaly; Ankit I Mehta; Dale Ding; Jenny K Hoang; Peter G Kranz; James E Herndon; April Coan; Ian Crocker; Anthony F Waller; Allan H Friedman; David A Reardon; John H Sampson
Journal:  J Neurosurg       Date:  2014-07-18       Impact factor: 5.115

4.  A novel method for volumetric MRI response assessment of enhancing brain tumors.

Authors:  Charles W Kanaly; Dale Ding; Ankit I Mehta; Anthony F Waller; Ian Crocker; Annick Desjardins; David A Reardon; Allan H Friedman; Darell D Bigner; John H Sampson
Journal:  PLoS One       Date:  2011-01-26       Impact factor: 3.240

Review 5.  Monitoring radiographic brain tumor progression.

Authors:  Ankit I Mehta; Charles W Kanaly; Allan H Friedman; Darell D Bigner; John H Sampson
Journal:  Toxins (Basel)       Date:  2011-03-15       Impact factor: 4.546

6.  Do Diametric Measurements Provide Sufficient and Reliable Tumor Assessment? An Evaluation of Diametric, Areametric, and Volumetric Variability of Lung Lesion Measurements on Computerized Tomography Scans.

Authors:  Aaron Frenette; Joshua Morrell; Kirk Bjella; Edward Fogarty; James Beal; Vijay Chaudhary
Journal:  J Oncol       Date:  2015-05-10       Impact factor: 4.375

7.  Clinical Evaluation of a Fully-automatic Segmentation Method for Longitudinal Brain Tumor Volumetry.

Authors:  Raphael Meier; Urspeter Knecht; Tina Loosli; Stefan Bauer; Johannes Slotboom; Roland Wiest; Mauricio Reyes
Journal:  Sci Rep       Date:  2016-03-22       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.