OBJECTIVE: To evaluate the effect of lesion length on in-stent restenosis (ISR) of vertebral artery (VA) origin stenting. METHODS: We retrospectively analyzed the medical and radiological records of patients receiving VA origin stenting from March 1999 to June 2005. They were subdivided according to lesion length. ISR was defined as >50% diameter narrowing in stent. RESULTS: Eighty symptomatic patients (64 male, mean age 72 years) with 90 lesions treated with balloon expandable tubular coronary stents were enrolled. There were 34 patients with 38 short lesions (length<or=5 mm, group 1), 37 patients with 42 medium lesions (length>5 mm, <10 mm, group 2) and 9 patients with 10 long lesions (length>or=10 mm, group 3). Eighty seven bare-metal stents and 3 drug-eluting stents were implanted. Repeat angiography was done in 40 lesions (44%) at 11.7+/-9.6 months. The ISR rate in group 1, 2, 3 is 21%, 29%, and 50% (p=0.486). Multivariable Cox regression analysis showed lesion length was the only significant independent predictor of ISR (hazard ratio: 1.19, p=0.039). CONCLUSION: ISR of VA origin stenting is common. Lesion length is an important predictor of ISR in VA origin stenting.
OBJECTIVE: To evaluate the effect of lesion length on in-stent restenosis (ISR) of vertebral artery (VA) origin stenting. METHODS: We retrospectively analyzed the medical and radiological records of patients receiving VA origin stenting from March 1999 to June 2005. They were subdivided according to lesion length. ISR was defined as >50% diameter narrowing in stent. RESULTS: Eighty symptomatic patients (64 male, mean age 72 years) with 90 lesions treated with balloon expandable tubular coronary stents were enrolled. There were 34 patients with 38 short lesions (length<or=5 mm, group 1), 37 patients with 42 medium lesions (length>5 mm, <10 mm, group 2) and 9 patients with 10 long lesions (length>or=10 mm, group 3). Eighty seven bare-metal stents and 3 drug-eluting stents were implanted. Repeat angiography was done in 40 lesions (44%) at 11.7+/-9.6 months. The ISR rate in group 1, 2, 3 is 21%, 29%, and 50% (p=0.486). Multivariable Cox regression analysis showed lesion length was the only significant independent predictor of ISR (hazard ratio: 1.19, p=0.039). CONCLUSION: ISR of VA origin stenting is common. Lesion length is an important predictor of ISR in VA origin stenting.
Authors: R Mohammadian; E Sharifipour; R Mansourizadeh; B Sohrabi; A R Nayebi; S Haririan; M Farhoudi; S Charsouei; S Najmi Journal: Neuroradiol J Date: 2013-08-27
Authors: Z Vajda; E Miloslavski; T Güthe; S Fischer; G Albes; A Heuschmid; H Henkes Journal: AJNR Am J Neuroradiol Date: 2009-09-03 Impact factor: 3.825
Authors: Hui Su; Shengyuan Yu; Chenglin Tian; Zhihua Du; Xinfeng Liu; Jun Wang; Xiangyu Cao Journal: Biomed Res Int Date: 2021-04-27 Impact factor: 3.411