Evaluation of three different specimen types (serum, plasma lithium heparin and serum gel separator) for analysis of certain analytes: clinical significance of differences in results and efficiency in use.

Myra P O'Keane1, Sean K Cunningham.   

Abstract

BACKGROUND: There is a lack of consensus regarding the most appropriate specimen type for analysis of many biochemistry analytes. The aim of this study was to compare renal and lipid analyte profiles and phenytoin values in plain serum (S), serum gel (G) and plasma (lithium heparin, P) tubes and to investigate the stability of these analytes after prolonged contact with cells or gel at room temperature (RT, 20 degrees C) and as aliquoted and stored at 4 degrees C.
METHODS: Primary specimens were centrifuged once, maintained at RT and analysed within 2 h (T(0)) and after 24 h (T(24)) and 48 h (T(48)). For assessment of stability at 4 degrees C, two cell-free aliquots were separated from each of the primary tubes and stored at 4 degrees C and then analysed at T(24) and T(48). Differences in analyte concentrations between tubes at T(0) and following storage (at T(24) and T(48)) were evaluated for both statistical and clinical significance.
RESULTS: At T(0) all analytes, except potassium, demonstrated equivalence between serum, gel and plasma tubes. Potassium and creatinine were more stable in gel tubes than in serum/plasma tubes. In contrast, phentytoin was stable in plain serum and plasma up to T(48) at RT, but showed a progressive and clinically significant decrease in concentration in gel tubes at T(24) and T(48) at RT. All analytes except CO(2) were stable up to T(48) when aliquoted and stored at 4 degrees C.
CONCLUSIONS: We concluded that the serum gel tube has advantages over plain serum and plasma tubes for measurement of the analytes investigated in this study, with the exception of phenytoin. In practice, the gel tubes demonstrate enhanced analyte stability and reduce the need to aliquot specimens, with greater protection against possible contamination. Further investigation would be required to evaluate a broader range of analytes.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16681442     DOI: 10.1515/CCLM.2006.099

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  11 in total

1.  A guide for measurement of circulating metabolic hormones in rodents: Pitfalls during the pre-analytical phase.

Authors:  Maximilian Bielohuby; Sarah Popp; Martin Bidlingmaier
Journal:  Mol Metab       Date:  2012-08-09       Impact factor: 7.422

2.  Effects of storage temperature and time on clinical biochemical parameters from rat serum.

Authors:  Carolyn Cray; Marilyn Rodriguez; Julia Zaias; Norman H Altman
Journal:  J Am Assoc Lab Anim Sci       Date:  2009-03       Impact factor: 1.232

3.  Comparison of the effect of gel used in two different serum separator tubes for thyroid function tests.

Authors:  Müjgan Ercan; Esra Fırat Oğuz; Emiş Deniz Akbulut; Mustafa Yilmaz; Turan Turhan
Journal:  J Clin Lab Anal       Date:  2018-03-07       Impact factor: 2.352

4.  Performance evaluation of a multiplex assay for future use in biomarker discovery efforts to predict body composition.

Authors:  Jennifer W Bea; Nicole C Wright; Patricia Thompson; Chengcheng Hu; Stefano Guerra; Zhao Chen
Journal:  Clin Chem Lab Med       Date:  2011-03-02       Impact factor: 3.694

5.  Comparison of red blood cell hemolysis using plasma and serum separation tubes for outpatient specimens.

Authors:  Dae-Hyun Ko; Dahae Won; Tae-Dong Jeong; Woochang Lee; Sail Chun; Won-Ki Min
Journal:  Ann Lab Med       Date:  2015-02-12       Impact factor: 3.464

6.  Abnormal gel flotation caused by contrast media during adrenal vein sampling.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Matteo Gelati; Antonella Bassi; Alberto Contro; Francesca Pizzolo; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2016-10-15       Impact factor: 2.313

7.  A comparative evaluation of lithium estimation for samples collected in different tubes and its stability on storage.

Authors:  Saidaiah Ikkurthi; Srinivas Balachander; Bela Goyal; Altaf Ahmad Mir; Subho Chakrabarti; Arnab Pal
Journal:  J Lab Physicians       Date:  2018 Jan-Mar

8.  Comparison of Barricor™ vs. lithium heparin tubes for selected routine biochemical analytes and evaluation of post centrifugation stability.

Authors:  Anne Marie Dupuy; Stéphanie Badiou; Delphine Daubin; Anne Sophie Bargnoux; Chloé Magnan; Kadda Klouche; Jean Paul Cristol
Journal:  Biochem Med (Zagreb)       Date:  2018-04-15       Impact factor: 2.313

9.  Sample Management: Stability of Plasma and Serum on Different Storage Conditions.

Authors:  Carlos Fernando Yauli Flores; Ángela de Las Mercedes Hurtado Pineda; Victoria Maritza Cevallos Bonilla; Klever Sáenz-Flor
Journal:  EJIFCC       Date:  2020-03-20

10.  Stability studies of common biochemical analytes in serum separator tubes with or without gel barrier subjected to various storage conditions.

Authors:  Serap Cuhadar; Ayşenur Atay; Mehmet Koseoglu; Ahmet Dirican; Aysel Hur
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.