| Literature DB >> 16678273 |
A Stafiej1, K Pyrzynska, A Ranz, E Lankmayr.
Abstract
For the study of the derivatization behavior of aliphatic C1-C10 aldehydes with 2,4-dinitrophenylhydrazine (DNPH) in a heating block a gradient elution HPLC method for separation and determination by UV detection at 360 nm was applied. The influence of time, temperature, excess of reagent and stirring onto the reaction yields were examined for conducting the reaction in a thermostated heating block. First, the derivatization procedure had been screened by experiments according to a complete factorial design in order to evaluate the statistically significant variables. Those parameters were used to establish the optimum conditions for the reaction by means of a Box-Behnken design.Entities:
Mesh:
Substances:
Year: 2006 PMID: 16678273 DOI: 10.1016/j.jbbm.2006.02.009
Source DB: PubMed Journal: J Biochem Biophys Methods ISSN: 0165-022X