| Literature DB >> 16670698 |
Daniel P Bulte1, Peter A Chiarelli, Richard G Wise, Peter Jezzard.
Abstract
Graded levels of supplemental inspired oxygen were investigated for their viability as a noninvasive method of obtaining intravascular magnetic resonance image contrast. Administered hyperoxia has been shown to be effective as a blood oxygenation level-dependent contrast agent for magnetic resonance imaging (MRI); however, it is known that high levels of inspired fraction of oxygen result in regionally decreased perfusion in the brain potentially confounding the possibility of using hyperoxia as a means of measuring blood flow and volume. Although the effects of hypoxia on blood flow have been extensively studied, the hyperoxic regime between normoxia and 100% inspired oxygen has been only intermittently studied. Subjects were studied at four levels of hyperoxia induced during a single session while perfusion was measured using arterial spin labelling MRI. Reductions in regional perfusion of grey matter were found to occur even at moderate levels of hyperoxia; however, perfusion changes at all oxygen levels were relatively mild (less than 10%) supporting the viability of hyperoxia-induced contrast.Entities:
Mesh:
Substances:
Year: 2006 PMID: 16670698 DOI: 10.1038/sj.jcbfm.9600319
Source DB: PubMed Journal: J Cereb Blood Flow Metab ISSN: 0271-678X Impact factor: 6.200