Literature DB >> 16650199

All troponins are not created equal.

S Jossi1, S L Gordon, M A Legge, G P Armstrong.   

Abstract

Troponin measurement is central to the management and risk stratification of acute coronary syndromes. Decisions are made by categorizing troponin as positive or negative. We sought to evaluate categorical agreement between four troponin assays. Sixty blood samples were analysed by three troponin I assays (Centaur, Architect and point-of-care i-STAT) and one troponin T (TnT) assay (Roche Elecys). The upper reference limit was taken as the lowest value with a coefficient of variation of 10% or less. Continuous agreement between assays was good (Pearson's correlation coefficient 0.871-0.995). Categorical agreement assessed by Cohen's kappa varied from poor (between Architect and Centaur kappa = 0.37, and between TnT and Centaur kappa = 0.48) to good (between Architect and i-STAT kappa = 0.68, and between TnT and i-STAT kappa = 0.68). Percentage of positive results varied almost twofold, from 37% for the Centaur to 72% for the Architect. Comparison of four troponin assays showed up to twofold variations in the proportion of positive results. This implies that either a large proportion of troponin-positive diagnoses are missed by some assays or the assays with higher positivity are generating large numbers of false positives. Clinicians should evaluate troponin results in the clinical context and not base decisions solely on the 'normal range' of their local troponin assay.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16650199     DOI: 10.1111/j.1445-5994.2006.01073.x

Source DB:  PubMed          Journal:  Intern Med J        ISSN: 1444-0903            Impact factor:   2.048


  4 in total

1.  Preconcentration and detection of the phosphorylated forms of cardiac troponin I in a cascade microchip by cationic isotachophoresis.

Authors:  Danny Bottenus; Mohammad Robiul Hossan; Yexin Ouyang; Wen-Ji Dong; Prashanta Dutta; Cornelius F Ivory
Journal:  Lab Chip       Date:  2011-09-21       Impact factor: 6.799

2.  Positive troponin-T in noncompaction is associated with neuromuscular disorders and poor outcome.

Authors:  J Finsterer; C Stöllberger; W Krugluger
Journal:  Clin Res Cardiol       Date:  2006-12-08       Impact factor: 5.460

3.  10,000-fold concentration increase of the biomarker cardiac troponin I in a reducing union microfluidic chip using cationic isotachophoresis.

Authors:  Danny Bottenus; Talukder Zaki Jubery; Yexin Ouyang; Wen-Ji Dong; Prashanta Dutta; Cornelius F Ivory
Journal:  Lab Chip       Date:  2011-03-07       Impact factor: 6.799

4.  10,000-fold concentration increase in proteins in a cascade microchip using anionic ITP by a 3-D numerical simulation with experimental results.

Authors:  Danny Bottenus; Talukder Zaki Jubery; Prashanta Dutta; Cornelius F Ivory
Journal:  Electrophoresis       Date:  2011-02-10       Impact factor: 3.535

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.