Literature DB >> 16649783

Scanning force microscopy and fluorescence microscopy of microcontact printed antibodies and antibody fragments.

John R LaGraff1, Quynh Chu-LaGraff.   

Abstract

Unlabeled primary immunoglobulin G (IgG) antibodies and its F(ab')2 and Fc fragments were attached to oxygen-plasma-cleaned glass substrates using either microcontact printing (MCP) or physical adsorption during bath application from dilute solutions. Fluorescently labeled secondary IgGs were then bound to surface-immobilized IgG, and the relative surface coverage was determined by measuring the fluorescence intensity. Results indicated that the surface coverage of IgG increased with increasing protein solution concentration for both MCP and bath-applied IgG and that a greater concentration of IgG was transferred to a glass substrate using MCP than during physisorption during bath applications. Scanning force microscopy (SFM) showed that patterned MCP IgG monolayers were 5 nm in height, indicating that IgG molecules lie flat on the substrate. After incubation with a secondary IgG, the overall line thickness increased to around 15 nm, indicating that the secondary IgG was in a more vertical orientation with respect to the substrate. The surface roughness of these MCP patterned IgG bilayers as measured by SFM was observed to increase with increasing surface coverage. Physisorption of IgG to both unmodified patterned polydimethylsiloxane (PDMS) stamps and plasma-cleaned glass substrates was modeled by Langmuir adsorption kinetics yielding IgG binding constants of K(MCP) = 1.7(2) x 10(7) M(-1) and K(bath) = 7.8(7) x 10(5) M(-1), respectively. MCP experiments involving primary F(ab')2 and Fc fragments incubated in fluorescently labeled fragment-specific secondary IgGs were carried out to test for the function and orientation of IgG. Finally, possible origins of MCP stamping defects such as pits, pull outs, droplets, and reverse protein transfer are discussed.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16649783     DOI: 10.1021/la0522303

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  5 in total

Review 1.  Electrochemical Biosensors - Sensor Principles and Architectures.

Authors:  Dorothee Grieshaber; Robert MacKenzie; Janos Vörös; Erik Reimhult
Journal:  Sensors (Basel)       Date:  2008-03-07       Impact factor: 3.576

2.  A patterned recombinant human IgM guides neurite outgrowth of CNS neurons.

Authors:  Xiaohua Xu; Nathan J Wittenberg; Luke R Jordan; Shailabh Kumar; Jens O Watzlawik; Arthur E Warrington; Sang-Hyun Oh; Moses Rodriguez
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

Review 3.  Design of surface modifications for nanoscale sensor applications.

Authors:  Erik Reimhult; Fredrik Höök
Journal:  Sensors (Basel)       Date:  2015-01-14       Impact factor: 3.576

4.  An Analysis of a Compact Label-Free Guiding-Wave Biosensor Based on a Semiconductor-Clad Dielectric Strip Waveguide.

Authors:  Carlos Angulo Barrios
Journal:  Sensors (Basel)       Date:  2020-06-14       Impact factor: 3.576

5.  A Simplified and Robust Activation Procedure of Glass Surfaces for Printing Proteins and Subcellular Micropatterning Experiments.

Authors:  Tina Karimian; Roland Hager; Andreas Karner; Julian Weghuber; Peter Lanzerstorfer
Journal:  Biosensors (Basel)       Date:  2022-02-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.