Literature DB >> 16649178

Pathophysiological advantages of rinsing-suction-reaming (RSR) in a pig model for intramedullary nailing.

Marc Schult1, Raphael Küchle, Alexander Hofmann, Tom Schmidt-Bräkling, Christian Ortmann, Esther Wassermann, Robert Schmidhammer, Heinz Redl, Alexander Joist.   

Abstract

Although reamed intramedullary nailing has been one of the greatest advances in modern fracture care, the concomitant increase in medullary cavity pressure leads to intravasation of bone marrow content into the blood stream, an effect that can evoke serious systemic reactions. A newly developed rinsing-suction-reamer (RSR) was able to substantially reduce the pressure and bone marrow intravasation content during experimental femoral nailing. We investigated the pathophysiological effects using the RSR, testing the hypothesis that by reducing marrow fat embolization, RSR would also reduce the activation of coagulation compared with the universal AO-Reamer (AOR) and comparable to external fixation. Twenty-two pigs were treated with either simulated external fixation or reamed femoral nailing using AOR or RSR. During surgery, the intramedullary pressure was measured and intravasation of medullary material was quantified. After surgery, the pigs were kept anaesthetised and monitored for 6 h. At defined intervals, serological, hematological, and hemodynamic parameters were evaluated. The RSR was significantly superior when compared to AOR with regard to the generation of intramedullary pressure and fat embolization; however, with external fixation the values were even lower. The evaluation of other parameters revealed no clear differences between the two reamers and the external fixator. The pig model showed that RSR led to a significant reduction of the intramedullary increase in pressure and fat intravasation compared to AOR. Although the reduction of fat embolism by RSR is not associated with pathophysiological changes, RSR can have advantages for the treatment of femoral fractures. (c) 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16649178     DOI: 10.1002/jor.20106

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  7 in total

Review 1.  Reamer-irrigator-aspirator indications and clinical results: a systematic review.

Authors:  George Cox; Elena Jones; Dennis McGonagle; Peter V Giannoudis
Journal:  Int Orthop       Date:  2011-01-18       Impact factor: 3.075

Review 2.  Complications associated using the reamer-irrigator -aspirator (RIA) system: a systematic review and meta-analysis.

Authors:  Markus Laubach; Lucas P Weimer; Felix M Bläsius; Frank Hildebrand; Philipp Kobbe; Dietmar W Hutmacher
Journal:  Arch Orthop Trauma Surg       Date:  2022-09-17       Impact factor: 2.928

3.  Bone graft harvest using a new intramedullary system.

Authors:  Mohan V Belthur; Janet D Conway; Gaurav Jindal; Ashish Ranade; John E Herzenberg
Journal:  Clin Orthop Relat Res       Date:  2008-10-08       Impact factor: 4.176

4.  Osteogenic potential of reamer irrigator aspirator (RIA) aspirate collected from patients undergoing hip arthroplasty.

Authors:  Ryan M Porter; Fangjun Liu; Carmencita Pilapil; Oliver B Betz; Mark S Vrahas; Mitchel B Harris; Christopher H Evans
Journal:  J Orthop Res       Date:  2009-01       Impact factor: 3.494

Review 5.  Early intramedullary nailing for femoral fractures in patients with severe thoracic trauma: A systemic review and meta-analysis.

Authors:  Xiao-Yuan Liu; Meng Jiang; C-L Yi; Xiang-Jun Bai; David-J Hak
Journal:  Chin J Traumatol       Date:  2016-06-01

6.  Adolescent Fat Embolism Syndrome after Closed Tibial Shaft Fracture: Treatment with Emergent External Fixation.

Authors:  Dillon C O'Neill; Graham J Dekeyser; Alexander J Mortensen; Christopher A Makarewich
Journal:  Case Rep Orthop       Date:  2021-04-24

7.  Complications and risk management in the use of the reaming-irrigator-aspirator (RIA) system: RIA is a safe and reliable method in harvesting autologous bone graft.

Authors:  Patrick Haubruck; Julian Ober; Raban Heller; Matthias Miska; Gerhard Schmidmaier; Michael C Tanner
Journal:  PLoS One       Date:  2018-04-26       Impact factor: 3.240

  7 in total