Literature DB >> 16648767

Resonance frequency analysis after the placement of 133 dental implants.

Araceli Boronat-López1, Miguel Peñarrocha-Diago, Orlando Martínez-Cortissoz, Ignacio Mínguez-Martínez.   

Abstract

INTRODUCTION: The primary stability of dental implants is related to the bone in contact with the latter, and can be evaluated by resonance frequency analysis.
MATERIAL AND METHODS: Measurements were made in 133 implants (62 in the upper jaw and 71 in the mandible) of resonance frequency and insertion force to determine implant stability on the day of surgery, with an evaluation of its relationship to different variables.
RESULTS: The stability quotient of the implants on the day of surgery was 62.1, with an insertion force of 35.7 N. The insertion force was proportional to the resonance frequency, with an increasing stability quotient with growing insertion force. The stability quotient was greater in the larger diameter implants, shorter implants, in mandibular placement and in areas of more compact bone.
CONCLUSIONS: The stability quotient on the day of implant placement is greater in higher bone density areas.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16648767

Source DB:  PubMed          Journal:  Med Oral Patol Oral Cir Bucal        ISSN: 1698-4447


  5 in total

1.  Influence of cortical bone anchorage on the primary stability of dental implants.

Authors:  Anne Kelly de Oliveira Nicolau Mantovani; Ivete Aparecida de Mattias Sartori; Luciana Reis Azevedo-Alanis; Rodrigo Tiossi; Flávia Noemy Gasparini Kiatake Fontão
Journal:  Oral Maxillofac Surg       Date:  2018-06-06

2.  Retrospective clinical study of an implant with a sandblasted, large-grit, acid-etched surface and internal connection: analysis of short-term success rate and marginal bone loss.

Authors:  Jae-Wang Lee; Jun Hyeong An; Sang-Hoon Park; Jong-Hyon Chong; Gwang-Seok Kim; JeongJoon Han; Seunggon Jung; Min-Suk Kook; Hee-Kyun Oh; Sun-Youl Ryu; Hong-Ju Park
Journal:  Maxillofac Plast Reconstr Surg       Date:  2016-11-05

3.  The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis.

Authors:  Anwar B Bataineh; Ala M Al-Dakes
Journal:  J Clin Exp Dent       Date:  2017-01-01

4.  Prospective multicenter non-randomized controlled study on intraosseous stability and healing period for dental implants in the posterior region.

Authors:  Shinya Homma; Yasushi Makabe; Takuya Sakai; Kenzou Morinaga; Satoru Yokoue; Hirofumi Kido; Yasutomo Yajima
Journal:  Int J Implant Dent       Date:  2018-03-29

5.  Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study.

Authors:  Juan Manuel Aragoneses; Javier Aragoneses; Vanessa Arlette Brugal; Margarita Gomez; Ana Suarez
Journal:  Medicina (Kaunas)       Date:  2020-05-27       Impact factor: 2.430

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.