Literature DB >> 16645981

Simultaneous enantioseparation and sensitive detection of eight beta-blockers using capillary electrochromatography-electrospray ionization-mass spectrometry.

Jack Zheng1, Shahab A Shamsi.   

Abstract

The feasibility of using vancomycin chiral stationary phase (CSP) and polar organic eluent is investigated for simultaneous enantioseparation of eight beta-blockers using CEC coupled to ESI mass spectrometric detection (ESI-MS). The internally tapered capillaries were utilized to pack CEC-MS columns. As compared to externally tapered columns, the use of internally tapered columns demonstrated enhanced stability, durability, and reproducibility. A mixture containing methanol/ACN/acetic acid/triethylamine at 70:30:1.6:0.2 v/v/v/v was considered as optimum mobile phase since it provided a good compromise between resolution and analysis time. As expected, sheath liquid and ESI-MS parameters mainly influenced the detection sensitivity. Interestingly, structural information of beta-blockers was available by varying the MS fragmentor voltage using in-house CID in the scan mode. In order to maximize the chiral/achiral resolution, various column-coupling approaches using teicoplanin as complementary CSP to vancomycin were tested. Several changes in the elution order of beta-blockers were observed using multimodal CSPs with some improvement in chiral or achiral resolution. The quantitative aspects of the CEC-MS method were demonstrated using R- and S-talinolol as internal standards. The calibration curves of beta-blockers showed good linearity in the range of 3-600 microM. The enantiomer of beta-blockers at a concentration of 30 nM was detectable. Furthermore, both 0.1 and 1% of the S-enantiomer could be precisely quantified in the presence of 99.9 and 99% of the R-isomer of beta-blocker.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16645981     DOI: 10.1002/elps.200500874

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

1.  High Throughput Analysis of Chiral Compounds Using Capillary Electrochromatography (CEC) and CEC-Mass Spectrometry with Cellulose Based Stationary Phases.

Authors:  William Bragg; Shahab A Shamsi
Journal:  Sep Sci Technol       Date:  2013       Impact factor: 2.475

2.  Development of a fritless packed column for capillary electrochromatography-mass spectrometry.

Authors:  William Bragg; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2011-10-08       Impact factor: 4.759

3.  Development of a chiral micellar electrokinetic chromatography-tandem mass spectrometry assay for simultaneous analysis of warfarin and hydroxywarfarin metabolites: application to the analysis of patients serum samples.

Authors:  Xiaochun Wang; Jingguo Hou; Michael Jann; Yuen Yi Hon; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2012-11-26       Impact factor: 4.759

4.  Optimized separation of beta-blockers with multiple chiral centers using capillary electrochromatography-mass spectrometry.

Authors:  William Bragg; Dean Norton; Shahab A Shamsi
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2008-11-01       Impact factor: 3.205

Review 5.  Past, present, and future developments in enantioselective analysis using capillary electromigration techniques.

Authors:  Nicky de Koster; Charles P Clark; Isabelle Kohler
Journal:  Electrophoresis       Date:  2020-09-28       Impact factor: 3.535

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.