Literature DB >> 16645945

Functionalized magnetic micro- and nanoparticles: optimization and application to micro-chip tryptic digestion.

Zuzana Bílková1, Marcela Slováková, Nicolas Minc, Claus Fütterer, Roxana Cecal, Daniel Horák, Milan Benes, Isabelle le Potier, Jana Krenková, Michael Przybylski, Jean-Louis Viovy.   

Abstract

The preparation of an easily replaceable protease microreactor for micro-chip application is described. Magnetic particles coated with poly(N-isopropylacrylamide), polystyrene, poly(2-hydroxyethyl methacrylate-co-ethylene dimethacrylate), poly(glycidyl methacrylate), [(2-amino-ethyl)hydroxymethylen]biphosphonic acid, or alginic acid with immobilized trypsin were utilized for heterogeneous digestion. The properties were optimized, with the constraint of allowing immobilization in a microchannel by a magnetic field gradient. To obtain the highest digestion efficiency, sub-micrometer spheres were organized by an inhomogeneous external magnetic field perpendicularly to the direction of the channel. Kinetic parameters of the enzyme reactor immobilized in micro-chip capillary (micro-chip immobilized magnetic enzyme reactor (IMER)) were determined. The capability of the proteolytic reactor was demonstrated by five model (glyco)proteins ranging in molecular mass from 4.3 to 150 kDa. Digestion efficiency of proteins in various conformations was investigated using SDS-PAGE, HPCE, RP-HPLC, and MS. The compatibility of the micro-chip IMER system with total and limited proteolysis of high-molecular-weight (glyco)proteins was confirmed. It opens the route to automated, high-throughput proteomic micro-chip devices.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16645945     DOI: 10.1002/elps.200500587

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

Review 1.  Nanobiocatalysis for protein digestion in proteomic analysis.

Authors:  Jungbae Kim; Byoung Chan Kim; Daniel Lopez-Ferrer; Konstantinos Petritis; Richard D Smith
Journal:  Proteomics       Date:  2010-02       Impact factor: 3.984

2.  In-line system containing porous polymer monoliths for protein digestion with immobilized pepsin, peptide preconcentration and nano-liquid chromatography separation coupled to electrospray ionization mass spectroscopy.

Authors:  Laurent Geiser; Sebastiaan Eeltink; Frantisek Svec; Jean M J Fréchet
Journal:  J Chromatogr A       Date:  2008-02-29       Impact factor: 4.759

3.  Magnetic particle-based hybrid platforms for bioanalytical sensors.

Authors:  Lia Stanciu; Yu-Ho Won; Mallikarjunarao Ganesana; Silvana Andreescu
Journal:  Sensors (Basel)       Date:  2009-04-23       Impact factor: 3.576

4.  Magnetic Particle Plug-Based Assays for Biomarker Analysis.

Authors:  Chayakom Phurimsak; Mark D Tarn; Nicole Pamme
Journal:  Micromachines (Basel)       Date:  2016-04-26       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.