Literature DB >> 16644776

Detection of donor-specific antibodies using HLA-coated microspheres: another tool for kidney transplant risk stratification.

Eric M Gibney1, Linda R Cagle, Brian Freed, Stephanie E Warnell, Larry Chan, Alexander C Wiseman.   

Abstract

BACKGROUND: Sensitive techniques are able to detect low levels of circulating antibodies. For many newer techniques, the clinical consequences of these antibodies are unknown. We hoped to determine the significance of antibodies detected through the use of Luminex microsphere-based assay.
METHODS: Patients who received kidney transplants between March 2003 and May 2004 with negative anti-human globulin-augmented complement-dependent cytotoxicity (AHG-CDC) crossmatches were retested for pre-transplant panel reactive antibodies (PRA) using Luminex microspheres and stored sera. Patients were considered to have circulating antibodies if either class I or class II Luminex PRA was >or=15%. These patients were then analysed for pre-transplant donor-specific antibodies (DSA). Clinical outcomes were compared in patients with and without DSAs.
RESULTS: Out of 136 patients who underwent transplantation, 55 had Luminex PRA >or=15%. Of these 55 patients, only 16 had a standard PRA >or=30% and 75% had a history of a sensitizing event. Twenty out of 55 patients were DSA+. Patients with DSA detected by Luminex had higher rates of primary non-function (PNF), delayed graft function, biopsy-proven acute rejection, and lower rates of graft survival at 6 months. A combined endpoint of immunological and clinical events was far more common in patients with DSA.
CONCLUSION: The detection of DSAs by Luminex microspheres was associated with significantly higher rates of graft dysfunction and immunological events. Conversely, the presence of antibodies but no DSA by Luminex was associated with excellent outcomes. In patients with negative AHG-CDC crossmatches, the occurrence of low-level DSA by Luminex could assist in identifying patients that require more aggressive immune monitoring or immunosuppressive strategies.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16644776     DOI: 10.1093/ndt/gfl202

Source DB:  PubMed          Journal:  Nephrol Dial Transplant        ISSN: 0931-0509            Impact factor:   5.992


  26 in total

1.  Monitoring of CD4+CD25highIL-7Rαhigh activated T cells in kidney transplant recipients.

Authors:  Laure Vallotton; Karine Hadaya; Jean-Pierre Venetz; Leo H Buehler; Donatella Ciuffreda; Ghaleb Nseir; Laura Codarri; Jean Villard; Giuseppe Pantaleo; Manuel Pascual
Journal:  Clin J Am Soc Nephrol       Date:  2011-07-14       Impact factor: 8.237

2.  Analysis of a high-throughput HLA antibody screening assay for use with platelet donors.

Authors:  Emmanuel Fadeyi; Sharon Adams; Brett Peterson; Julia Hackett; Phyllis Byrne; Harvey G Klein; Francesco M Marincola; Susan F Leitman; David F Stroncek
Journal:  Transfusion       Date:  2008-04-15       Impact factor: 3.157

Review 3.  Sensitive solid-phase detection of donor-specific antibodies as an aid highly relevant to improving allograft outcomes.

Authors:  Gerald Schlaf; Beatrix Pollok-Kopp; Wolfgang W Altermann
Journal:  Mol Diagn Ther       Date:  2014-04       Impact factor: 4.074

4.  Preformed circulating HLA-specific memory B cells predict high risk of humoral rejection in kidney transplantation.

Authors:  Marc Lúcia; Sergi Luque; Elena Crespo; Edoardo Melilli; Josep M Cruzado; Jaume Martorell; Marta Jarque; Salvador Gil-Vernet; Anna Manonelles; Josep M Grinyó; Oriol Bestard
Journal:  Kidney Int       Date:  2015-07-15       Impact factor: 10.612

5.  Characteristics of Circulating Donor Human Leukocyte Antigen-specific Immunoglobulin G Antibodies Predictive of Acute Antibody-mediated Rejection and Kidney Allograft Failure.

Authors:  Dinesh Kannabhiran; John Lee; Joseph E Schwartz; Rex Friedlander; Meredith Aull; Thangamani Muthukumar; Sean Campbell; David Epstein; Surya V Seshan; Sandip Kapur; Vijay K Sharma; Manikkam Suthanthiran; Darshana Dadhania
Journal:  Transplantation       Date:  2015-06       Impact factor: 4.939

6.  Pregnancy-Induced Sensitization Promotes Sex Disparity in Living Donor Kidney Transplantation.

Authors:  Bianca Bromberger; Danielle Spragan; Sohaib Hashmi; Alexander Morrison; Arwin Thomasson; Susanna Nazarian; Deirdre Sawinski; Paige Porrett
Journal:  J Am Soc Nephrol       Date:  2017-05-08       Impact factor: 10.121

Review 7.  Donor-specific antibodies adversely affect kidney allograft outcomes.

Authors:  Sumit Mohan; Amudha Palanisamy; Demetra Tsapepas; Bekir Tanriover; R John Crew; Geoffrey Dube; Lloyd E Ratner; David J Cohen; Jai Radhakrishnan
Journal:  J Am Soc Nephrol       Date:  2012-11-15       Impact factor: 10.121

Review 8.  Sensitized renal transplant recipients: current protocols and future directions.

Authors:  James Gloor; Mark D Stegall
Journal:  Nat Rev Nephrol       Date:  2010-03-16       Impact factor: 28.314

Review 9.  Transplant immuno-diagnostics: crossmatch and antigen detection.

Authors:  Andrew M South; Paul C Grimm
Journal:  Pediatr Nephrol       Date:  2015-07-03       Impact factor: 3.714

10.  Complement-dependent cytotoxicity (CDC) to detect Anti-HLA antibodies: old but gold.

Authors:  Patrícia Keiko Saito; Roger Haruki Yamakawa; Lucieni Christina Marques da Silva Pereira; Waldir Veríssimo da Silva; Sueli Donizete Borelli
Journal:  J Clin Lab Anal       Date:  2014-02-27       Impact factor: 2.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.