Literature DB >> 16644200

Comparison of amperometric biosensors fabricated by palladium sputtering, palladium electrodeposition and Nafion/carbon nanotube casting on screen-printed carbon electrodes.

Chung-Hun Lee1, Shih-Chang Wang, Chiun-Jye Yuan, Meng-Fang Wen, Ku-Shang Chang.   

Abstract

Different strategies, including palladium electrodeposition (Pd(CV)), Pd sputtering (Pd(S)) and Nafion-solubilized carbon nanotube casting (Nafion/CNT), were used to modify screen-printed carbon electrodes (SPCEs) for the fabrication of amperometric enzyme biosensors. The electrochemical properties of the bare and modified SPCEs and the optimal conditions for surface modification were determined. The electrochemical response of the bare SPCE to H(2)O(2) under the potential of 0.3 V could be improved about 100-fold by Pd modification by electrodeposition or sputtering. By contrast, the electrochemical response of the bare SPCE was enhanced by only about 11-fold by Nafion/CNT casting. Moreover, the Pd(CV)-SPCEs exhibited better reproducibility of electrochemical response (a relative standard deviation (R.S.D.)<6.0%) than freshly prepared Pd(S)-SPCEs (R.S.D.>10%). The glucose biosensor fabricated from Pd-modified electrodes could be stored for up to 108 days without loosing significant activity. The Pd(CV)-SPCE also showed very reliable signal characteristics upon 50 consecutively repeated measurements of ascorbic acid. The electrocatalytic detection of the Pd-SPCE was combined with additional advantages of resistance to surface fouling and hence good stability. In conclusion, this study demonstrated that deposition of Pd thin film on SPCEs by electrodeposition or sputtering provided superior enhancement of electrochemical properties compared to Nafion/CNT-SPCEs. Despite their high electrochemical response, Pd(S)-SPCEs required an activation process to improve stability and Pd(CV)-SPCEs suffered from poor between electrode reproducibility.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16644200     DOI: 10.1016/j.bios.2006.03.008

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Modulation of fibroblast inflammatory response by surface modification of a perfluorinated ionomer.

Authors:  Thelma I Valdes; Winston Ciridon; Buddy D Ratner; James D Bryers
Journal:  Biointerphases       Date:  2011-06       Impact factor: 2.456

2.  High sensitivity electrochemical cholesterol sensor utilizing a vertically aligned carbon nanotube electrode with electropolymerized enzyme immobilization.

Authors:  Anurat Wisitsoraat; Chanpen Karuwan; Krongkamol Wong-Ek; Ditsayut Phokharatkul; Pornpimol Sritongkham; Adisorn Tuantranont
Journal:  Sensors (Basel)       Date:  2009-10-29       Impact factor: 3.576

3.  Enzyme immobilization strategies and electropolymerization conditions to control sensitivity and selectivity parameters of a polymer-enzyme composite glucose biosensor.

Authors:  Sharon A Rothwell; Sarah J Killoran; Robert D O'Neill
Journal:  Sensors (Basel)       Date:  2010-06-30       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.