Literature DB >> 16643288

Biomechanical effects of splint types on traumatized tooth: a photoelastic stress analysis.

Sevi Burcak Cengiz1, Atilla Stephan Atac, Zafer C Cehreli.   

Abstract

This study was undertaken to assess the effect of splint type on stresses occurring around traumatized tooth by photoelastic stress analysis. Three semi-rigid splint types--a wire-composite splint, fiberglass splint and titanium trauma splint--were utilized for comparisons. Extracted left upper central and lateral incisors and the canine tooth of an otherwise healthy patient were embedded equidistantly in photoelastic resin. For all cases studied, a static axial and 20 degrees oblique force of 100 N was applied on the lateral incisor in separate sessions. The experiments were undertaken without any splint application (unsplinted, control) after which the splints, adhesively bonded to the labial aspects of teeth, were consecutively tested. During each loading sequence, generation of isochromatic fringes was observed in the field of a polariscope, and photographed by a digital camera. Quantification of fringes was performed on magnified images, transferred to a PC. Under vertical loading, the highest stresses in the apical regions were observed for the unsplinted and ribbond-splint groups, whereas the lowest fringes occurred with the use of orthodontic wire as a splinting medium. Titanium trauma splint had absolutely no effect on reduction of stresses, as the fringe orders were slightly higher than the unsplinted lateral tooth. The use of orthodontic wire resulted in lowest fringe orders around the traumatized tooth.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16643288     DOI: 10.1111/j.1600-9657.2006.00339.x

Source DB:  PubMed          Journal:  Dent Traumatol        ISSN: 1600-4469            Impact factor:   3.333


  3 in total

Review 1.  Autotransplantation of teeth in humans: a systematic review and meta-analysis.

Authors:  Konstantinia Almpani; Spyridon N Papageorgiou; Moschos A Papadopoulos
Journal:  Clin Oral Investig       Date:  2015-04-24       Impact factor: 3.573

Review 2.  Use of Orthodontic Methods in the Treatment of Dental Luxations: A Scoping Review.

Authors:  Enrico Spinas; Laura Pipi; Silvia Mezzena; Luca Giannetti
Journal:  Dent J (Basel)       Date:  2021-02-04

3.  Influence of preoperative degree of tooth loosening and thickness of wire on the rigidity of wire composite splint.

Authors:  Archana Aravind; Vijay Kumar; Sidhartha Sharma; Amrita Chawla; Ajay Logani
Journal:  J Conserv Dent       Date:  2022-03-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.