Literature DB >> 16642802

Quantitative measurements of acoustic emissions from cavitation at the surface of a stone in response to a lithotripter shock wave.

Parag V Chitnis1, Robin O Cleveland.   

Abstract

Measurements are presented of acoustic emissions from cavitation collapses on the surface of a synthetic kidney stone in response to shock waves (SWs) from an electrohydraulic lithotripter. A fiber optic probe hydrophone was used for pressure measurements, and passive cavitation detection was used to identify acoustic emissions from bubble collapse. At a lithotripter charging voltage of 20 kV, the focused SW incident on the stone surface resulted in a peak pressure of 43 +/- 6 MPa compared to 23 +/- 4 MPa in the free field. The focused SW incident upon the stone appeared to be enhanced due to the acoustic emissions from the forced cavitation collapse of the preexisting bubbles. The peak pressure of the acoustic emission from a bubble collapse was 34 +/- 15 MPa, that is, the same magnitude as the SWs incident on the stone. These data indicate that stresses induced by focused SWs and cavitation collapses are similar in magnitude thus likely play a similar role in stone fragmentation.

Entities:  

Mesh:

Year:  2006        PMID: 16642802     DOI: 10.1121/1.2177589

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  4 in total

1.  A comparison of light spot hydrophone and fiber optic probe hydrophone for lithotripter field characterization.

Authors:  N Smith; G N Sankin; W N Simmons; R Nanke; J Fehre; P Zhong
Journal:  Rev Sci Instrum       Date:  2012-01       Impact factor: 1.523

2.  In vitro comminution of model renal calculi using histotripsy.

Authors:  Alexander P Duryea; Adam D Maxwell; William W Roberts; Zhen Xu; Timothy L Hall; Charles A Cain
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-05       Impact factor: 2.725

3.  Probability of cavitation for single ultrasound pulses applied to tissues and tissue-mimicking materials.

Authors:  Adam D Maxwell; Charles A Cain; Timothy L Hall; J Brian Fowlkes; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2013-02-04       Impact factor: 2.998

4.  Customization of the acoustic field produced by a piezoelectric array through interelement delays.

Authors:  Parag V Chitnis; Paul E Barbone; Robin O Cleveland
Journal:  J Acoust Soc Am       Date:  2008-06       Impact factor: 2.482

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.