Literature DB >> 16641788

Microbubble contrast for radiological imaging: 1. Principles.

Peter N Burns1, Stephanie R Wilson.   

Abstract

Microbubble contrast for ultrasound imaging in radiology has finally come of age, adding entirely new capabilities to real time imaging. Following a bolus injection into a peripheral vein of as little as 0.1mL of an aqueous suspension, contrast specific imaging modes show parenchymal and lesional perfusion in real time in the major organs of the abdomen and pelvis as well as breast, thyroid and prostate. These new imaging modes exploit the unique interaction between ultrasound and microbubbles, which gives rise to nonlinear echoes that are readily distinguishable from those of tissue. Furthermore, microbubbles can be deliberately disrupted by the ultrasound imaging field. The rate at which fresh bubbles then replenish the scanplane can be metered in subsequent images, offering a means to quantify both flowrate and relative vascular volume of the microvasculature in both organs and solid lesions.

Mesh:

Substances:

Year:  2006        PMID: 16641788

Source DB:  PubMed          Journal:  Ultrasound Q        ISSN: 0894-8771            Impact factor:   1.657


  19 in total

Review 1.  Active surveillance for low-risk prostate cancer: an update.

Authors:  Nathan Lawrentschuk; Laurence Klotz
Journal:  Nat Rev Urol       Date:  2011-04-26       Impact factor: 14.432

2.  Study of neurinomas with ultrasound contrast media: review of a case series to identify characteristic imaging patterns.

Authors:  A De Marchi; S Pozza; R Sutera; E M Brach del Prever; M Petraz; C Sena; A Linari; C Faletti
Journal:  Radiol Med       Date:  2011-03-07       Impact factor: 3.469

3.  Safety of ultrasound contrast agents in the pediatric oncologic population: a single-institution experience.

Authors:  Jamie L Coleman; Fariba Navid; Wayne L Furman; M Beth McCarville
Journal:  AJR Am J Roentgenol       Date:  2014-05       Impact factor: 3.959

Review 4.  The role of CEUS in the assessment of haemodynamically stable patients with blunt abdominal trauma.

Authors:  Fabio Pinto; Massimo Valentino; Laura Romanini; Raffaella Basilico; Vittorio Miele
Journal:  Radiol Med       Date:  2014-08-21       Impact factor: 3.469

5.  Contrast-enhanced sonography of malignant pediatric abdominal and pelvic solid tumors: preliminary safety and feasibility data.

Authors:  M Beth McCarville; Sue C Kaste; Fredric A Hoffer; Raja B Khan; R Christopher Walton; Bruce S Alpert; Wayne L Furman; Chenghong Li; Xiaoping Xiong
Journal:  Pediatr Radiol       Date:  2012-01-17

Review 6.  Targeted microbubbles: a novel application for the treatment of kidney stones.

Authors:  Krishna Ramaswamy; Vanessa Marx; Daniel Laser; Thomas Kenny; Thomas Chi; Michael Bailey; Mathew D Sorensen; Robert H Grubbs; Marshall L Stoller
Journal:  BJU Int       Date:  2015-03-17       Impact factor: 5.588

7.  Nonlinear Imaging of Microbubble Contrast Agent Using the Volterra Filter: In Vivo Results.

Authors:  Juan Du; Dalong Liu; Emad S Ebbini
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-09-29       Impact factor: 2.725

8.  Can contrast-enhanced ultrasound evaluate the severity of acute pancreatitis?

Authors:  Qiang Lu; Yue Zhong; Xiao-rong Wen; Zong-wen Huang; Yu-ting Fan; Qing Xia; Yan Luo
Journal:  Dig Dis Sci       Date:  2010-11-28       Impact factor: 3.199

Review 9.  Image guidance for focal therapy of prostate cancer.

Authors:  U Lindner; N Lawrentschuk; J Trachtenberg
Journal:  World J Urol       Date:  2010-10-21       Impact factor: 4.226

10.  Changes in lipid-encapsulated microbubble population during continuous infusion and methods to maintain consistency.

Authors:  Mehmet Kaya; Thomas S Gregory; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2009-07-26       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.