Literature DB >> 16640052

[The influence of IOL implantation on visual acuity, contrast sensitivity and colour vision 2 and 4 months after cataract surgery].

J Ventruba1.   

Abstract

PURPOSE: To assess the change in visual acuity, contrast sensitivity and colour vision in relation to the time after cataract surgery and to the type of implanted IOL, and to compare visual functions by patients with one and two pseudophakic eyes.
METHODS: 45 cataract patients were examined before and then 2 and 4 month after the cataract surgery. Visual acuity (VA) was tested on logMAR optotype chart with Landolt rings, contrast sensitivity (CS) was tested on the Pelli-Robson chart and the SWCT chart. For colour vision (CV) testing, the standard Farnsworth D-15 test and the desaturated Lanthony D-15 test were used. The patients were divided into two groups--a group with one pseudophakic eye and a group with two pseudophakic eyes, and also according to the type of IOL--PMMA or hydrophobic acrylate that had been implanted. Control group was composed of phakic subjects with no ocular pathology.
RESULTS: After the cataract surgery, in both groups there was a significant improvement in monocular and binocular VA (p < 0.05), in monocular and binocular CS using both types of charts--Pelli-Robson (p < 0.05) and SWCT in all the spatial frequencies (p < 0.05). Also, a significant decrease in the number of minor errors in the standard Farnsworth D-15 test (p < 0.05) as well as a substantial decrease in the number of minor and major errors in the desaturated Lanthony D-15 test (p < 0.05) and an overall improvement of CV (p < 0.05) were detected. There was no difference between the results 2 and 4 month after the surgery, except for CS in 12 c/deg (p < 0.05). The patients with two pseudophakic eyes had postoperatively better binocular VA and CS in the spatial frequencies of 12 c/deg and 18 c/deg and attained postoperative values comparable to those of control subjects. No significant difference in VA, CS or CV was found between the PMMA and hydrophobic acrylate intraocular lenses.
CONCLUSION: After the cataract surgery, the visual functions tested by means of psychophysical methods of VA, CS and CV significantly improve and are stable 2 month after the surgery. The second eye surgery improves binocular visual functions the level of which doesn't differ from that of normal phakic subjects. There was no influence of the type of IOL on final state of VA, CS or CV.

Entities:  

Mesh:

Year:  2006        PMID: 16640052

Source DB:  PubMed          Journal:  Cesk Slov Oftalmol        ISSN: 1211-9059


  2 in total

1.  Impairment of Colour Vision in Diabetes with No Retinopathy: Sankara Nethralaya Diabetic Retinopathy Epidemiology and Molecular Genetics Study (SNDREAMS- II, Report 3).

Authors:  Laxmi Gella; Rajiv Raman; Vaitheeswaran Kulothungan; Swakshyar Saumya Pal; Suganeswari Ganesan; Tarun Sharma
Journal:  PLoS One       Date:  2015-06-08       Impact factor: 3.240

2.  Color vision abnormalities in type II diabetes: Sankara Nethralaya Diabetic Retinopathy Epidemiology and Molecular Genetics Study II report no 2.

Authors:  Laxmi Gella; Rajiv Raman; Vaitheeswaran Kulothungan; Swakshyar Saumya Pal; Suganeswari Ganesan; Sangeetha Srinivasan; Tarun Sharma
Journal:  Indian J Ophthalmol       Date:  2017-10       Impact factor: 1.848

  2 in total