Literature DB >> 16639610

Partial volume effect correction in SPECT for striatal uptake measurements in patients with neurodegenerative diseases: impact upon patient classification.

Marine Soret1, Pierre Malick Koulibaly, Jacques Darcourt, Irène Buvat.   

Abstract

PURPOSE: In single-photon emission computed tomography (SPECT) of the dopaminergic system, measurements of striatal uptake are useful for diagnosis and patient follow-up but are strongly biased by the partial volume effect (PVE). We studied whether PVE correction might improve patient classification based on binding potential (BP) measurements.
METHODS: Patients with a probable diagnosis of dementia with Lewy bodies (DLB, 10 patients) or Alzheimer's disease (AD, 13 patients) were studied by( 123)I-FP-CIT SPECT. SPECT images were reconstructed with and without PVE correction. Each patient SPECT scan was also simulated to obtain SPECT data whose characteristics were fully known. In addition, 17 SPECT scans were simulated with striatal uptake values mimicking pre-symptomatic cases of DLB.
RESULTS: Without PVE correction, mean putamen BP values were 2.9+/-0.4 and 0.9+/-0.2 for AD and DLB patients respectively, while with PVE correction, they were 8.6+/-1.5 and 1.9+/-0.5 respectively. All patients were properly identified as having AD or DLB when considering mean putamen BP measured on their real or simulated SPECT scan, with and without PVE correction. All 30 simulations mimicking pre-symptomatic DLB and AD patients were accurately classified with PVE correction, but without PVE correction 15 mean putamen BP values were in a range where AD and DLB could not be distinguished.
CONCLUSION: We conclude that putamen BP values measured without PVE correction can be used to differentiate probable DLB and AD due to the already severe reduction in dopamine transporter levels. PVE correction appeared useful for accurate differential diagnosis between AD and pre-symptomatic DLB.

Entities:  

Mesh:

Year:  2006        PMID: 16639610     DOI: 10.1007/s00259-005-0003-4

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  32 in total

1.  European Association of Nuclear Medicine procedure guidelines for brain neurotransmission SPET using (123)I-labelled dopamine D(2) transporter ligands.

Authors:  K Tatsch; S Asenbaum; P Bartenstein; A Catafau; C Halldin; L S Pilowsky; A Pupi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-10       Impact factor: 9.236

2.  Quantitative accuracy of dopaminergic neurotransmission imaging with (123)I SPECT.

Authors:  Marine Soret; Pierre Malick Koulibaly; Jacques Darcourt; Sébastien Hapdey; Irène Buvat
Journal:  J Nucl Med       Date:  2003-07       Impact factor: 10.057

Review 3.  Imaging of the dopaminergic neurotransmission system using single-photon emission tomography and positron emission tomography in patients with parkinsonism.

Authors:  J Booij; G Tissingh; A Winogrodzka; E A van Royen
Journal:  Eur J Nucl Med       Date:  1999-02

4.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

5.  Effects of scatter and attenuation correction on quantitative analysis of beta-CIT brain SPET.

Authors:  J Hashimoto; T Sasaki; K Ogawa; A Kubo; N Motomura; T Ichihara; T Amano; Y Fukuuchi
Journal:  Nucl Med Commun       Date:  1999-02       Impact factor: 1.690

6.  Patterns of cerebral atrophy in dementia with Lewy bodies using voxel-based morphometry.

Authors:  E J Burton; G Karas; S M Paling; R Barber; E D Williams; C G Ballard; I G McKeith; P Scheltens; F Barkhof; J T O'Brien
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

7.  Dopamine transporter brain imaging to assess the effects of pramipexole vs levodopa on Parkinson disease progression.

Authors: 
Journal:  JAMA       Date:  2002-04-03       Impact factor: 56.272

8.  Differentiation of dementia with Lewy bodies from Alzheimer's disease using a dopaminergic presynaptic ligand.

Authors:  Z Walker; D C Costa; R W H Walker; K Shaw; S Gacinovic; T Stevens; G Livingston; P Ince; I G McKeith; C L E Katona
Journal:  J Neurol Neurosurg Psychiatry       Date:  2002-08       Impact factor: 10.154

9.  Presymptomatic diagnosis of experimental Parkinsonism with 123I-PE2I SPECT.

Authors:  Caroline Prunier; Erwan Bézard; Jérôme Montharu; Marina Mantzarides; Jean-Claude Besnard; Jean-Louis Baulieu; Christian Gross; Denis Guilloteau; Sylvie Chalon
Journal:  Neuroimage       Date:  2003-07       Impact factor: 6.556

10.  Dementia with Lewy bodies versus Alzheimer's disease: role of dopamine transporter imaging.

Authors:  Durval C Costa; Zuzana Walker; Rodney W H Walker; Flávia R G Fontes
Journal:  Mov Disord       Date:  2003-10       Impact factor: 10.338

View more
  10 in total

1.  Proposal for the standardisation of multi-centre trials in nuclear medicine imaging: prerequisites for a European 123I-FP-CIT SPECT database.

Authors:  John Caddell Dickson; Livia Tossici-Bolt; Terez Sera; Robin de Nijs; Jan Booij; Maria Claudia Bagnara; Anita Seese; Pierre Malick Koulibaly; Umit Ozgur Akdemir; Cathrine Jonsson; Michel Koole; Maria Raith; Markus Nowak Lonsdale; Jean George; Felicia Zito; Klaus Tatsch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-01       Impact factor: 9.236

2.  Calibration of gamma camera systems for a multicentre European ¹²³I-FP-CIT SPECT normal database.

Authors:  Livia Tossici-Bolt; John C Dickson; Terez Sera; Robin de Nijs; Maria Claudia Bagnara; Catherine Jonsson; Egon Scheepers; Felicia Zito; Anita Seese; Pierre Malick Koulibaly; Ozlem L Kapucu; Michel Koole; Maria Raith; Jean George; Markus Nowak Lonsdale; Wolfgang Münzing; Klaus Tatsch; Andrea Varrone
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-06       Impact factor: 9.236

3.  Chronic coffee consumption and striatal DAT-SPECT findings in Parkinson's disease.

Authors:  Angelo Fabio Gigante; Artor Niccoli Asabella; Giovanni Iliceto; Tommaso Martino; Cristina Ferrari; Giovanni Defazio; Giuseppe Rubini
Journal:  Neurol Sci       Date:  2018-01-23       Impact factor: 3.307

4.  FDG PET evaluation of early axillary lymph node response to neoadjuvant chemotherapy in stage II and III breast cancer patients.

Authors:  Caroline Rousseau; Anne Devillers; Mario Campone; Loïc Campion; Ludovic Ferrer; Christine Sagan; Myriam Ricaud; Boumédiène Bridji; Françoise Kraeber-Bodéré
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-02-10       Impact factor: 9.236

5.  A direct ROI quantification method for inherent PVE correction: accuracy assessment in striatal SPECT measurements.

Authors:  Eleonora Vanzi; Maria Teresa De Cristofaro; Silvia Ramat; Barbara Sotgia; Mario Mascalchi; Andreas Robert Formiconi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-03-28       Impact factor: 9.236

6.  [123I]FP-CIT ENC-DAT normal database: the impact of the reconstruction and quantification methods.

Authors:  Livia Tossici-Bolt; John C Dickson; Terez Sera; Jan Booij; Susanne Asenbaun-Nan; Maria C Bagnara; Thierry Vander Borght; Cathrine Jonsson; Robin de Nijs; Swen Hesse; Pierre M Koulibaly; Umit O Akdemir; Michel Koole; Klaus Tatsch; Andrea Varrone
Journal:  EJNMMI Phys       Date:  2017-01-28

7.  Novel approach to semi-quantification of tracer accumulation in dopamine transporter scan.

Authors:  Yoshinori Ito; Naotoshi Fujita; Kazuhiro Hara; Tomohiro Tada; Shinji Abe; Masahisa Katsuno; Shinji Naganawa; Katsuhiko Kato
Journal:  J Appl Clin Med Phys       Date:  2022-05-10       Impact factor: 2.243

8.  The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation.

Authors:  Piero Calvini; Guido Rodriguez; Fabrizio Inguglia; Alessandro Mignone; Ugo Paolo Guerra; Flavio Nobili
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-08       Impact factor: 10.057

9.  Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators.

Authors:  Keishin Morita; Akira Maebatake; Rina Iwasaki; Yuki Shiotsuki; Kazuhiko Himuro; Shingo Baba; Masayuki Sasaki
Journal:  Asia Ocean J Nucl Med Biol       Date:  2018

10.  Validation of Optimum ROI Size for 123I-FP-CIT SPECT Imaging Using a 3D Mathematical Cylinder Phantom.

Authors:  Hideo Onishi; Takayuki Sakai; Osamu Shiromoto; Hizuru Amijima
Journal:  Asia Ocean J Nucl Med Biol       Date:  2018
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.