Dissociation of biomolecules using a ultraviolet matrix-assisted laser desorption/ionisation time-of-flight/curved field reflectron tandem mass spectrometer equipped with a differential-pumped collision cell.

Omar Belgacem1, Andrew Bowdler, Ian Brookhouse, Francesco L Brancia, Emmanuel Raptakis.   

Abstract

A commercial matrix-assisted laser desorption/ionisation time-of-flight (MALDI-ToF) instrument equipped with a curved field reflectron (CFR) was modified in order to perform collision-induced dissociation (CID) on a variety of biomolecules. The incorporation of a high-resolution ion gate together with a collision cell within the field-free region allowed tandem mass analysis (MS/MS), without the necessity to decelerate the precursor ions prior to activation. The simultaneous detection of all product ions remained possible by using the CFR. To test the MS/MS performances, ACTH (fragment 1-17), a complex high mannose carbohydrate (Man)(8)(GlcNac)(2) and a lysophosphatidylcholine lipid (18:1) were analysed on the modified instrument. Direct comparison with the low-energy product ion spectra, acquired on a MALDI quadrupole ion trap (QIT) two-stage reflectron time-of flight (ReToF) mass spectrometer, showed significant differences in the types of product ions observed. The additional ions detected were a clear indication of the high-energy fragmentation processes occurring in the collision cell. Copyright (c) 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16636997     DOI: 10.1002/rcm.2486

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  The renaissance of high-energy CID for structural elucidation of complex lipids: MALDI-TOF/RTOF-MS of alkali cationized triacylglycerols.

Authors:  Ernst Pittenauer; Günter Allmaier
Journal:  J Am Soc Mass Spectrom       Date:  2009-02-27       Impact factor: 3.109

2.  Detailed structural analysis of lipids directly on tissue specimens using a MALDI-SpiralTOF-Reflectron TOF mass spectrometer.

Authors:  Shuichi Shimma; Ayumi Kubo; Takaya Satoh; Michisato Toyoda
Journal:  PLoS One       Date:  2012-05-18       Impact factor: 3.240

3.  Axial spatial distribution focusing: improving MALDI-TOF/RTOF mass spectrometric performance for high-energy collision-induced dissociation of biomolecules.

Authors:  O Belgacem; E Pittenauer; M E Openshaw; P J Hart; A Bowdler; G Allmaier
Journal:  Rapid Commun Mass Spectrom       Date:  2016-02-15       Impact factor: 2.419