Literature DB >> 16636406

Parametric EIT for monitoring cardiac stroke volume.

S Zlochiver1, D Freimark, M Arad, A Adunsky, S Abboud.   

Abstract

The bio-impedance technique appears appropriate for non-invasive cardiac stroke volume (SV) measurement, as the thoracic conductivity distribution is altered during the cardiac cycle due to the heart contraction and blood perfusion. In the present work, the feasibility of a parametric electrical impedance tomography (EIT) for assessing the cardiac SV was studied. An impedance model of the thorax was constructed from segmented axial MRI images along 19 phases of the cardiac cycle. The heart was simulated as an ellipsoid, with its axes' lengths set as the reconstruction parameters, while all other tissues' geometry and conductivity values were kept fixed. A Newton-Raphson parametric optimization scheme was utilized, yielding a correlation between the reconstructed and anatomical left ventricular volumes of 0.97 (p = 2 x 10(-11)). An analysis of noise sensitivity showed that the proposed algorithm requires an SNR greater than 65 dB. The simulation results were compared to physical data, collected with a portable EIT system (PulmoTrace, CardioInspect). The validation study was employed for a group of N = 28 healthy patients, and a comparison with impedance cardiography measurements (BioZ, Cardiodynamics) was made, showing a correlation of r = 0.86 (p = 4 x10(-9)). The preliminary results demonstrate that parametric EIT has the potential to measure SV, and may be applicable for both clinical and home environment usage.

Entities:  

Mesh:

Year:  2006        PMID: 16636406     DOI: 10.1088/0967-3334/27/5/S12

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  2 in total

1.  Electrical impedance tomography for non-invasive identification of fatty liver infiltrate in overweight individuals.

Authors:  Chih-Chiang Chang; Zi-Yu Huang; Shu-Fu Shih; Yuan Luo; Arthur Ko; Qingyu Cui; Jennifer Sumner; Susana Cavallero; Swarna Das; Wei Gao; Janet Sinsheimer; Alex Bui; Jonathan P Jacobs; Päivi Pajukanta; Holden Wu; Yu-Chong Tai; Zhaoping Li; Tzung K Hsiai
Journal:  Sci Rep       Date:  2021-10-06       Impact factor: 4.996

2.  Non-Invasive Electrical Impedance Tomography for Multi-Scale Detection of Liver Fat Content.

Authors:  Yuan Luo; Parinaz Abiri; Shell Zhang; Chih-Chiang Chang; Amir H Kaboodrangi; Rongsong Li; Ashish K Sahib; Alex Bui; Rajesh Kumar; Mary Woo; Zhaoping Li; René R Sevag Packard; Yu-Chong Tai; Tzung K Hsiai
Journal:  Theranostics       Date:  2018-02-08       Impact factor: 11.556

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.