Literature DB >> 16634418

The Narcotrend monitor.

S Kreuer1, W Wilhelm.   

Abstract

The Narcotrend (MonitorTechnik, Bad Bramstedt, Germany) is an EEG monitor designed to measure the depth of anaesthesia. It has been developed at the University Medical School of Hannover, Germany, has been commercially available for 5 years and has meanwhile received US Food and Drug Administration approval. The Narcotrend algorithm is based on pattern recognition of the raw electroencephalogram (EEG) and classifies the EEG traces into different stages from A (awake) to F (increasing burst suppression down to electrical silence). The newest Narcotrend software version includes a dimensionless Narcotrend index from 100 (awake) to 0 (electrical silence). The raw EEG signal can be recorded by standard electrocardiogram electrodes for single- and double-channel registration. The Narcotrend monitor provides a vast amount of information: the actual Narcotrend stage and index, the trend ('cerebrogram'), the raw EEG signal and a power spectrum and several derived EEG parameters. Multiple clinical and validation studies are available for the Narcotrend monitor, including comparisons with the BIS monitor (Aspect Medical Systems, Natick, USA).

Mesh:

Year:  2006        PMID: 16634418     DOI: 10.1016/j.bpa.2005.08.010

Source DB:  PubMed          Journal:  Best Pract Res Clin Anaesthesiol        ISSN: 1521-6896


  18 in total

Review 1.  Clinical Electroencephalography for Anesthesiologists: Part I: Background and Basic Signatures.

Authors:  Patrick L Purdon; Aaron Sampson; Kara J Pavone; Emery N Brown
Journal:  Anesthesiology       Date:  2015-10       Impact factor: 7.892

Review 2.  [Pharmacokinetic-pharmacodynamic models for inhaled anaesthetics].

Authors:  S Kreuer; J Bruhn; W Wilhelm; T Bouillon
Journal:  Anaesthesist       Date:  2007-06       Impact factor: 1.041

3.  Monitoring the level of hypnosis using a hierarchical SVM system.

Authors:  Ahmad Shalbaf; Reza Shalbaf; Mohsen Saffar; Jamie Sleigh
Journal:  J Clin Monit Comput       Date:  2019-04-15       Impact factor: 2.502

4.  The Feasibility and Utility of Continuous Sleep Monitoring in Critically Ill Patients Using a Portable Electroencephalography Monitor.

Authors:  Susana Vacas; Erin McInrue; Michael A Gropper; Mervyn Maze; Rochelle Zak; Eunjung Lim; Jacqueline M Leung
Journal:  Anesth Analg       Date:  2016-07       Impact factor: 5.108

Review 5.  Noninvasive Monitoring and Potential for Patient Outcome.

Authors:  Susana Vacas; Maxime Cannesson
Journal:  J Cardiothorac Vasc Anesth       Date:  2019-08       Impact factor: 2.628

6.  Intraoperative reduction of vasopressors using processed electroencephalographic monitoring in patients undergoing elective cardiac surgery: a randomized clinical trial.

Authors:  C Sponholz; C Schuwirth; L Koenig; H Hoyer; S M Coldewey; C Schelenz; T Doenst; A Kortgen; M Bauer
Journal:  J Clin Monit Comput       Date:  2019-02-19       Impact factor: 2.502

7.  Failure of two commercial indexes and spectral parameters to reflect the pharmacodynamic effect of desflurane on EEG.

Authors:  Sascha Kreuer; Jörgen Bruhn; Richard Ellerkmann; Stephan Ziegeler; Darius Kubulus; Wolfram Wilhelm
Journal:  J Clin Monit Comput       Date:  2008-03-27       Impact factor: 2.502

Review 8.  Monitoring the depth of anaesthesia.

Authors:  Bojan Musizza; Samo Ribaric
Journal:  Sensors (Basel)       Date:  2010-12-03       Impact factor: 3.576

9.  Narcotrend-guided intraoperative care of a Trisomy 21 paediatric patient who underwent occipitocervical fusion.

Authors:  Evangeline Ko Villa; Dominic Villa; Rafael C Bundoc
Journal:  BMJ Case Rep       Date:  2020-02-11

10.  Capability of processed EEG parameters to monitor conscious sedation in endoscopy is similar to general anaesthesia.

Authors:  Jakob Garbe; Stephan Eisenmann; Jan W Kantelhardt; Florian Duenninghaus; Patrick Michl; Jonas Rosendahl
Journal:  United European Gastroenterol J       Date:  2021-02-11       Impact factor: 4.623