Literature DB >> 16632744

Quantitative analysis and effect of attenuation correction on lymph node staging of non-small cell lung cancer on SPECT and CT.

Shinya Shiraishi1, Seiji Tomiguchi, Daisuke Utsunomiya, Koichi Kawanaka, Kazuo Awai, Syoji Morishita, Tomoko Okuda, Koichi Yokotsuka, Yasuyuki Yamashita.   

Abstract

OBJECTIVE: The purpose of our study was to assess quantitative indexes and the effect of attenuation correction on the evaluation of lymph node metastasis in the staging of non-small cell lung cancer (NSCLC) using fused thallium-201 SPECT/CT images.
MATERIALS AND METHODS: We evaluated 156 lymph nodes (66 metastatic, 90 nonmetastatic) from 29 patients with NSCLC. Using our combined SPECT/CT system, all patients underwent 201Tl SPECT and CT examinations immediately (early images) and 3 hr after (delayed images) the injection of 201Tl. SPECT images were reconstructed with and without attenuation correction. For the quantitative evaluation of lymph node metastasis, we calculated the early ratio, the delayed ratio, and the washout ratio for SPECT images and the short-axis diameter for CT images. Receiver operating characteristic (ROC) analysis was performed in each index for the differentiation between metastatic and nonmetastatic lymph nodes. Visual analysis was also performed by two experienced radiologists.
RESULTS: The area under the ROC curve (A(z)) showed that early ratio and delayed ratio were superior to short-axis diameter for the assessment of lymph node metastasis. In addition, early and delayed ratios on attenuation-corrected images were superior to those ratios on images without attenuation correction. However, the A(z) value for washout ratio was smaller than that for short-axis diameter. Early ratio on attenuation-corrected images was the most useful index (A(z) = 0.94). The sensitivity, specificity, and accuracy for early ratio on attenuation-corrected images were 78.8%, 94.4%, and 87.8% for the diagnosis of lymph node metastasis and 84.6%, 100%, and 93.1% for clinical staging (N0-N1 vs N2-N3), respectively. Fused images showed significantly higher diagnostic accuracy than CT images on visual analysis.
CONCLUSION: Quantitative assessment using fused SPECT/CT images is useful for the diagnosis of lymph node metastasis in patients with NSCLC.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16632744     DOI: 10.2214/AJR.04.0898

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

Review 1.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

2.  Quantitative index calculated by (99m)Tc-GSA scintigraphy.

Authors:  Morikatsu Yoshida; Shinya Shiraishi; Noriko Tsuda; Fumi Sakamoto; Seiji Tomiguchi; Yasuyuki Yamashita
Journal:  Chin J Cancer Res       Date:  2014-12       Impact factor: 5.087

3.  Prediction of sentinel lymph node status using single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging of breast cancer.

Authors:  Mai Tomiguchi; Mutsuko Yamamoto-Ibusuki; Yutaka Yamamoto; Mamiko Fujisue; Shinya Shiraishi; Touko Inao; Kei-ichi Murakami; Yumi Honda; Yasuyuki Yamashita; Ken-ichi Iyama; Hirotaka Iwase
Journal:  Surg Today       Date:  2015-04-19       Impact factor: 2.549

4.  Liver functional volumetry for portal vein embolization using a newly developed 99mTc-galactosyl human serum albumin scintigraphy SPECT-computed tomography fusion system.

Authors:  Toru Beppu; Hiromitsu Hayashi; Hirohisa Okabe; Toshiro Masuda; Kosuke Mima; Ryu Otao; Akira Chikamoto; Koichi Doi; Takatoshi Ishiko; Hiroshi Takamori; Morikatsu Yoshida; Shinya Shiraishi; Yasuyuki Yamashita; Hideo Baba
Journal:  J Gastroenterol       Date:  2011-04-27       Impact factor: 7.527

5.  Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis.

Authors:  Michael T Hirschmann; Christopher R Wagner; Helmut Rasch; Johann Henckel
Journal:  BMC Med Imaging       Date:  2012-03-29       Impact factor: 1.930

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.